Cecilware

®

Water Boilers

Thermostat Adjustment

The Thermostat is factory set for proper dispense
temperature of 200°F ± 3°F (93°C ± 16°C) with the
control knob set to the maximum clockwise position. If
field adjustments are needed proceed as follows: 
• 

To DECREASE temperature

, turn the control knob

slightly in the COUNTERCLOCKWISE direction. 

• To INCREASE the water temperature - 

1. With the Thermostat Knob to its maximum

clockwise position, remove the knob and locate the
slotted adjustment screw inside the hollow
thermostat shaft. 

2. Using a narrow-bladed screwdriver, engage slotted

adjustment screw and turn it 1/4 turn slowly
counter-clockwise. 

3. Allow a few minutes for the temperature to reach

set level. The Heater Light will go ON, indicating the
heating element is activated, wait for it to go OFF,
indicating that the water has reached new set
temperature. 

4. Take a temperature reading and repeat if necessary.

Adjustments

WARNING: SHOCK AND BURN HAZARD

To prevent electric shock and burn hazard this
procedure must be performed by a trained and
qualified service technician.

WARNING: SHOCK HAZARD

Disconnect power before attempting any electrical
repairs.

Thermostat Adjustment

Thermostat Bulb

Coupling

Nut

CCW - Decrease

Temperature

Summary of Contents for CME10E-N

Page 1: ...9 Wiring Diagram 10 Thank you for purchasing this quality boiler For your safety and the safety of others read all warnings and the operator manual before installing or using the product Properly inst...

Page 2: ...ock damage unit and will void warranty To reduce risk of explosion or fire do not use near combustibles WARNING Safety Information 2 Cecilware Water Boilers Important Safety Information This is the sa...

Page 3: ...300 25 5 1 10 AWG 240 10 500 25 3 10 AWG 208 7 900 22 3 10 AWG NOTE 1 FIELD WIRING MUST BE SUITABLE FOR 75 DEGREES CELSIUS 2 USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTION 3 120 VOLT UNITS SUPPLIED...

Page 4: ...ce such as a double check valve to be installed between the machine and the water supply Incoming pressure should be greater than 30 psi and not more than 70 psi NOTICE Connecting the water boiler to...

Page 5: ...nit with a damp cloth using soap solution or a non abrasive compound when required Sanitizing 1 With power to the unit disconnected fill unit to capacity 2 Prepare a sanitizing solution in accordance...

Page 6: ...stat shaft 2 Using a narrow bladed screwdriver engage slotted adjustment screw and turn it 1 4 turn slowly counter clockwise 3 Allow a few minutes for the temperature to reach set level The Heater Lig...

Page 7: ...NOT TURN ON THERMOSTAT UNTIL BOILER IS PRIMED Replacing Thermostat Thermostat is located in side box of boiler Lift off side box door to gain access to thermostat then follow instructions below 1 Shut...

Page 8: ...ll does not flow after the wire is disconnected from the Probe the problem may be in the Solid State Dual Level Control Board 3 If water starts flowing into the tank the Probe may be grounded due to e...

Page 9: ...Water Boilers Cecilware 9 Parts Diagram...

Page 10: ...10 Cecilware Water Boilers Wiring Diagram...

Page 11: ...Water Boilers Cecilware 11 Wiring Diagram continued...

Page 12: ...12 Cecilware Water Boilers Wiring Diagram continued...

Page 13: ...tinued 1 PHASE 240 VOLTS G197A 2 x 3 5 KW TOTAL 7 KW 3 PHASE 240 VOLTS G197A 3 x 3 5 KW TOTAL 10 5 KW CONTACTOR CONTACTOR TERMINAL BLOCK L1 L2 N TERMINAL BLOCK L1 L2 L3 N SHEET 4 of 4 ELECTRICAL DIAGR...

Page 14: ...14 Cecilware Water Boilers...

Page 15: ...Water Boilers Cecilware 15...

Page 16: ...lware 4003 Collins Lane Louisville KY 40245 USA Phone 502 425 4776 Toll Free 800 695 4500 Fax 502 425 4664 Web gmcw com Email info gmcw com 2016 Grindmaster Cecilware Printed in USA 0516 Form CW 328 0...

Reviews: