![Cebora POWER ROD 1350 Service Manual Download Page 6](http://html1.mh-extra.com/html/cebora/power-rod-1350/power-rod-1350_service-manual_2577556006.webp)
CEBORA S.p.A.
6
3.302.050
22/12/00
Correct?
Correct?
Correct?
3.2.2
- Starting the power source.
q
System shut off and disconnected from the mains.
q
In MMA, connect the electrode clamp to the positive pole of the power source, and the cable
of the negative pole of the power source to the workpiece.
q
In TIG, connect the TIG torch (suggested torch T150, art. 1567.01 Cebora) to the negative
pole of the power source and the cable of the positive pole of the power source to the
workpiece.
q
Connect the power source to the mains.
q
Close the switch (F).
♦
System powered, lamp on the switch (F) lit.
♦
Fan (16) running, yellow led (B) and green (C ) lit (lamp-test).
♦
After three seconds, yellow led (B) off, output voltage generation starts.
NO (see 3.3.1-3.3.2-
3.3.3-3.3.4)
YES
WARNING
DURING THE FOLLOWING TESTS DO NOT AIM THE TORCH AT PEOPLE OR PARTS
OF THE BODY, BUT ONLY TOWARDS AN OPEN SPACE OR THE WORKPIECE.
q
Set by the knob (A) the current based on the electrode you intend to use.
q
Move the electrode clip or the torch near the workpiece.
♦
Begin welding. Adjust the knob (A) to maximize the welding quality.
NO (see 3.3.5-3.3.6).
YES
At welding end remove electrode clamp or the torch from the workpiece.
♦
The arc shuts off immediately, power source returns in open circuit output voltage
generation condition, yellow led (B) off, green led (C ) lit.
NO (see 3.3.4).
YES
REGULAR OPERATION.