![Cebora POWER PLASMA 3100 Service Manual Download Page 27](http://html1.mh-extra.com/html/cebora/power-plasma-3100/power-plasma-3100_service-manual_2577554027.webp)
CEBORA S.p.A.
27
3.302.089
31/05/02
5.6
- HF board (22) code 5.602.074/C.
5.6.1
- Topographical drawing.
5.6.2
- Connector table.
Connector
Terminals
Function
J1
1
gas solenoid valve (20) relay command input.
J1
2
HF relay command input.
J1
3
board digital circuits 0 Vdc power supply input.
J1
4 – 5
“start” command output.
J1
6,7
+13.8 Vdc board power supply input.
J1
8
“transfer arc” signal output from reed on HF board (22).
J2
1 – 2
enable output for gas solenoid valve (20).
-
J3 – J4
HF generator circuit power supply input.
-
FISS1 (+) – J5 (-) voltage input for electrode and nozzle/earth.
J6
A – B
input from start button on the torch.
J6
E
output voltage for torch nozzle.
-
TP5
output voltage for torch electrode.
-
FISS2
output for earth terminal (potential of the workpiece).