12

2.3 EXPLANATION OF THE TECHNICAL SPECIFICA-

TIONS LISTED ON THE  MACHINE PLATE.

The equipment is manufactured according to these 

 

international standards: IEC 60974.1-IEC 60974.3-IEC 
60974.10 CL. A-IEC 61000-3-11-IEC 61000-3-12 (See note 2).

 ransformer threephase-rectifier-

 

converter DC/DC (chopper).

N°. 

Serial number, which must be indicated on 
any request regarding the equipment. 

 

Drooping characteristic.

P.A.C.  Suitable for plama cutting.

torch type  Welding torch type which can be used with 

this   equipment.

U0 

Secondary open-circuit voltage (peak value).

Duty cycle percentage.

 

The duty cycle expresses the percentage of 
10 minutes during which the equipment may 
run at a certain current without overheating.

I2 

Cutting current.

U2 

Secondary voltage with I2 cutting current.

 

This voltage depends on the distance be-
tween nozzle and the workpiece. 

If this dis-

tance increases also the cutting voltage 
increases and the duty cycle X% may de

-

crease

.

U1 

Rated supply voltage.

3~ 50/60Hz  50- or 60-Hz three-phase power supply.
I1 max. 

This is the maximum value of the absorbed   
current.

l1 eff. 

This is the maximum value of the actual cur-
rent absorbed, considering the duty cycle.

IP21  

Degree of housing protection.

 Degree 

1

 as the second digit means that this 

device is not suitable for use outdoors.

S

 

This device is not suitable for use outdoors.

 

Suitable for use in high-risk environments.

NOTES: 
1- The equipment has also been designed for use in envi-

ronments with a pollution rating of 3. (See IEC 60664).

2- This equipment complies with IEC 61000-3-11 provid-

ed that the maximum permissible system impedance 

Zmax is less than or equal to 0,034 hom at the inter-

face point between the user’s supply and the public 

system. It is the responsibility of the installer or user 

of the equipment to ensure, by consultation with the 

distribution network operator if necessary, that the 

equipment is connected only to a supply with maxi-

mum permissible system impedance Zmax  less than 
or equal to 0,034 hom.

  3   INSTALLATION

3.1 WELDING TORCH ASSEMBLY

This equipment is supplied without welding torch and 

P

N

O W

U

Z

V

A

B

Z

H

F

E

L

K

J

I

H

T

R

S

Q

D

C

Fig. 2

Summary of Contents for PLASMA PROF 163 ACC

Page 1: ...orch lead and work cables If the electrode torch lead cable is on your right side the work cable should also be on your right side Connect the work cable to the workpiece as close as possible to the a...

Page 2: ...machine or cutting 7 Do not remove or paint over cover the label 2 GENERAL DESCRIPTION This equipment is a direct current continuous power source designed for plasma arc cutting of electro con ductin...

Page 3: ...50 60Hz 50 or 60 Hz three phase power supply I1 max This is the maximum value of the absorbed current l1 eff This is the maximum value of the actual cur rent absorbed considering the duty cycle IP21...

Page 4: ...LED s N O P T and S will glow The following data will be rapidly displayed power source code display U installed firmware version display V name of assembled welding torch display U and V Then display...

Page 5: ...UGING GOUGE OPERATING MODE only for CP161 torches This operation makes it possible to remove defective welds to separate welded pieces to prepare edges etc For this operation use a 3 mm nozzle The val...

Page 6: ...oxidation of the electrode and noz zle and may make pilot arc start up more difficult If this condition is present clean the electrode terminal end and the nozzle interior with thin abrasive paper Ma...

Page 7: ...lly as soon as the temperature returns within the allo wed limits If the problem persists call CEBORA Service Department Gas inlet pressure low GAS LO Err 78 Increase the gas inlet pressure Guard on H...

Page 8: ...SLUITEND BESTEMD VOOR BEVOEGD PERSONEEL DENNA DEL R ENDAST AVSEDD F R KVALIFICERAD PERSONAL AUTO V TO TMH VMA PROORIVZETAI APOKLEISTIKAV GIA TO EIDIKEUME VNO PROSWPIKO V CODIFICA COLORI CABLAGGIO ELET...

Page 9: ...87...

Page 10: ...88...

Page 11: ...TEZIONE PROTECTION 25 SUPPORTO MANICO HANDLE SUPPORT 26 MANICO HANDLE 27 PANNELLO ANTERIORE FRONT PANEL 28 CONNESSIONE CONNECTION 29 CIRCUITO SENSORE SENSOR CIRCUIT 30 ADATTATORE FISSO FIXED ADAPTOR P...

Page 12: ...o inossidabile Stainless steel Alluminio Aluminium Corrente di taglio Cutting current Spessore Thickness Velocit di taglio Cutting speed Spessore Thickness Velocit di taglio Cutting speed Spessore Thi...

Page 13: ...lity Qualit Quality Produzione Production A mm V m min mm mm s mm 40 1 87 8 00 10 00 1 5 3 0 0 1 0 6 40 2 92 6 00 6 60 1 5 3 0 0 1 0 9 40 3 98 3 30 4 00 1 5 3 0 0 2 1 2 40 5 101 1 50 2 00 1 5 5 0 0 4...

Page 14: ...0 141 1 30 1 51 4 0 7 0 0 6 1 9 60 12 146 0 90 1 02 4 0 7 0 0 7 2 1 60 15 155 0 45 0 51 4 0 8 0 1 0 2 3 60 20 158 0 30 0 42 4 0 N A 2 6 60 25 169 0 15 0 19 4 0 N A 3 2 60 30 183 0 07 0 08 4 0 N A 4 0...

Page 15: ...00 1 40 4 0 7 0 0 9 2 2 100 20 143 0 80 0 91 4 0 7 0 1 2 2 8 100 25 149 0 50 0 60 4 0 N A 2 9 100 30 155 0 30 0 40 4 0 N A 3 2 100 35 160 0 25 0 30 4 0 N A 3 3 100 40 166 0 15 0 19 4 0 N A 3 4 100 4...

Page 16: ...00 2 80 4 0 7 0 0 7 2 2 120 15 135 1 25 1 60 4 0 7 0 0 8 2 4 120 20 141 0 92 1 06 4 0 8 0 1 0 2 7 120 25 147 0 55 0 71 4 0 N A 3 0 120 30 153 0 38 0 50 4 0 N A 3 3 120 35 162 0 25 0 36 4 0 N A 3 5 120...

Page 17: ...0 136 1 30 1 52 4 0 9 0 0 8 3 2 160 25 141 0 80 1 00 4 0 N A 3 5 160 30 143 0 69 0 76 4 0 N A 3 9 160 35 149 0 50 0 57 4 0 N A 4 1 160 40 155 0 37 0 41 4 0 N A 4 2 160 45 160 0 25 0 28 4 0 N A 4 2 160...

Page 18: ...96 CEBORA S p A Via Andrea Costa 24 40057 Cadriano di Granarolo BOLOGNA Italy Tel 39 051 765 000 Fax 39 051 765 222 www cebora it e mail cebora cebora it...

Reviews: