background image

13

(180mm - 7.1in) and height 

MAX

 (1000mm - 39.4in) or 

only 1 cylinder having diameter 

MAX

 (220mm – 8.7in) 

and height MAX (1600mm – 63in). The cylinders must be 

firmly  fixed  to  the  cylinder  shelf  by  means  of  the  belts 

provided. 
The gas cylinder must be equipped with a pressure reg-
ulator and  a gauge.
Only after positioning the cylinder, connect the outgoing 
gas hose from the rear panel of the machine to the pres-
sure regulator.
Open the mobile lateral side, mount the wire coil on its 
support, insert the wire coming out of the wire coil into 
the gear motor, and make sure that wire type and diam-
eter are the same as drive roller ones. The wire must be  
aligned with the roller race and come out of the adapter 

C

. Close the drive arm, fit the welding torch and the earth 

cable on socket 

D

.

After  fitting  the  reel  and  torch,  switch  on  the  machine, 

select the synergic curve suitable to the type of wire to 
be welded, following the instructions given in the service 
functions (

PROCESS PARAMS

) paragraph. Remove 

the gas nozzle and unscrew the current nozzle of the 
torch. Press the torch button until the wire comes out. 

BE CAREFUL to keep your face away from the end 

lance while the wire is coming out

, screw up the current 

nozzle and fit the gas nozzle.
Open the canister adapter and adjust the gas flow to 8 – 

10 l/min.
During welding, the display screen 

A

 displays the actual 

work current and voltage. The displayed values may be 
slightly different to those set. This can depend on numerous 
different factors - type of torch, thickness different to 
nominal thickness, distance between current nozzle and 
the material being welded, and the welding speed. After 
welding, the current and voltage values remain stored on 
the display 

A

. To display the set values, the handle 

will 

have to be moved slightly, while, by pushing the torch 
button without welding, the display screen 

A

 shows the 

empty voltage value and a current value of 0.

  6 DESCRIPTION OF FUNCTIONS SHOWN    

 

     ON THE DISPLAY SCREEN A.
 

When the machine is switched 
on, for a few moments the 
display screen 

A

 displays: the 

article number of the machine, 
the version and development 
date of the software, and the 

release number of the synergic curves (this information is also 
given in Section 7.1 SERVICE FUNCTIONS).
Immediately after switch-on, the display screen 

A

 shows:

The synergic curve used, the welding mode 

2T,

 

4T 

or 

3L, SPOT

 function, if active, the letters 

PP

 if a push-pull 

welding torch is used,  the welding process "

SHORT

 or 

PULSED

"

(optional)

, the welding current, the speed of 

the welding wire in metres/min, the welding voltage and 
the recommended thickness. To increase or decrease the 
welding parameters, simply adjust by means of knob 

B

The values all change together in a 

synergic

 way.

To change the welding voltage 

V,

 simply press the knob 

B

 

for less than 2 seconds. The display screen will show (

Arc 

Length

) an adjustment bar with central 0. The value can 

be changed by means of the knob 

B

 from -9.9 to 9.9. To 

exit from the function, briefly press the knob 

B

.

By changing the value, once having exited the sub-menu, 
alongside the voltage 

V

, an arrow will appear turned 

upwards to indicate a higher adjustment of the set value, 
while the arrow turned downwards will indicate a lower 
adjustment.

6.1 

SERVICE FUNCTIONS (PROCESS PARAMS) 

SHOWN ON THE DISPLAY SCREEN A. 

To access these functions, we must start from the main 
display page and press the knob 

B

 for at least 2 seconds.

To enter the function, simply select it by means of the 
knob 

B

 and press it for less than 2 seconds. To return 

to the main display page, press the knob 

for at least 2 

seconds.
The functions which can be selected are: 

• 

Synergic curve (Wire Selection)

  To choose the synergic curve, by means of the knob 

B

, it is necessary to select and press on the curve 

presented by the display screen 

A

. Simply select the 

curve  of  interest  and  confirm  the  choice  by  pressing 

the knob 

for less than 2 seconds. 

  After pressing the knob 

B

 return is made to the previous 

display page (

PROCESS PARAMS

).

Summary of Contents for JAGUAR E 200 MD

Page 1: ...frequency H F can interfere with ra dio navigation safety services computers and communications equipment Have only qualified persons familiar with electronic equipment perform this installa tion The...

Page 2: ...nt U1 Rated supply voltage 1 50 60Hz Single phase 50 or 50 Hz power supply I1 Max Max absorbed current at the corresponding I2 current and U2 voltage I1 eff This is the maximum value of the actual cur...

Page 3: ...culation of air inside and as much as possible prevent metal or other dusts from penetrating Position the weld ing machine in an area that ensures good stability The weight of the welding machine is a...

Page 4: ...t value of 0 6 DESCRIPTION OF FUNCTIONS SHOWN ON THE DISPLAY SCREEN A When the machine is switched on for a few moments the display screen A displays the article number of the machine the version and...

Page 5: ...rent or crater filling at the welding end Crater Curr Possibility of adjusting from 10 to 200 of the set welding current Welding starts at the welding torch button pressure The named current will be t...

Page 6: ...the crater filling current Crater Curr from 10 to 200 of the welding current Default 60 The time C C Time of the crater filling duration may also be adjusted from 0 1 to 10 seconds default 0 5 seconds...

Page 7: ...ng the knob B for less than 2 seconds Themes This function changes the display colours Options LOCK To access this function simply highlight it using the knob B and press it for less than 2 seconds Th...

Page 8: ...4 4 standard 7 1 GENERATOR MAINTENANCE In case of maintenance inside the appliance make sure the switch F is in O position and that the power supply cable is disconnected from the mains Periodically a...

Reviews: