background image

I-53

I-53

The I-53 is an automatism-clock for hour signals, with an independent activation for hours, and others thanks to 
two relays. It could be used during 24 Hours or only during the day with two different time-tables. You could 
introduce two connection times for fours and other. 
It includes manual function to activate outputs when you wish.  
It also includes signal led, hourly visualisation, keyboard, battery, front panel, connection terminals to make 

OPERATING.

OPERATING.

2

TIMERS

I-53

I-53

Ref. Full9809

TIMER FOR CLOCK AND BELL.

TECHNICAL CHARACTERISTICS.

Voltage. ..........................................................................................12 V. DC.
Minimum Consumption. ................................................................50 mA.
Maximum Consumption. ...............................................................150 mA.

Minimum Connection Time for Hours and Others Relays. ............ 0.5 sec.

Battery. .......................................................................................... CR-20 (3 V.)
Protection against polarity inversion . ............................................ Yes.

Maximum Admissible Load. ...........................................................3 A.

Maximum Connection Time for Hours and Others relays. ............ 1 sec.
Hour Format. ................................................................................. 24 H.
Displays. ........................................................................................ 4 x 0.5“ Displays (13.5 mm.) and led.

POWER SUPPLY 

: The I-53 circuit had to be supplied by a 12 VDC power supply perfectly stabilised and we suggest 

you to not use rectifier or power supply not stabilised to avoid to damage the module.
Then, we recommended you the FE-2 power supply which has been developed to perfectly answer to the circuit 
needs. Connect the positive of the power supply to the positive terminal indicated in the wiring map, then 
connect also the negative of the power supply to the negative terminal indicated in the circuit.  

Verify

 that the 

assembly has been correctly done.

OPERATING 

: The I-53 module is an automatism to imitate the operating Bell clock, indicating hours and others. 

Then, the hour relay will be activated each hour and the second relay will be activated each 15 minutes. The 
module had been designed on a quartz oscillator basis, guaranteeing a maximum exactitude. It also includes 
different options offering it a wide applications range.

HOW TO ADJUST HOUR 

: The module had a clock to control the automatism and to visualise the hour. Before to 

activate the module in its definitive application, you have to adjust it. Then, you have to maintain pressed the 
"enter" push button placed in the front of the module till the LD1 led will light on. At this moment both hour 
displays will intermittently light and minutes display will be fixed. 
When you are adjusting the hour, do not forget that you only modify fix displays because intermittent display are 

in stand by. Then, you could firstly adjust minutes displays pressing on "up" and "Down" push buttons to increase or 
decrease the number. If you maintain pressed any of these two button, the change will be quickly done.

Once minutes adjusted, you have to press the "enter" button to fix hours displays and intermittent minutes 
displays. Then, you could adjust wished hours pressing "up" and "down" buttons. 
Therefore if you press the "enter" button you stop the adjustment and LD1 led will light off. 

OUTPUTS TIMING 

: At each pulse, hours and others outputs could be adjusted according to possible connection 

times : 0,5 and 1 sec. See the drawing Nº1 to find the selector indicated as INT-1 and two switches in OFF position 
which corresponding outputs offer 0,5 sec. Impulses. 
Then, if you place these switches in ON position, the corresponding output will offer 1 sec. Impulses. 

1 control the configuration of the module to operate in 24 Hours or daily mode.  If you place this switch in OFF 
position, the I-53 module will generate impulses during 24 Hours, but if you place it in ON position, the module 
only generate impulses during several hours a day (that you could configure thanks to the switch Nº2). 
The switch Nº2 control the operating hours to allow to the module generate impulses for the daily mode. If you 
place this switch in OFF position, the operating margin is established between 8 :00 A.M and 22 P.M. If you place 
it in ON position, the margin will established between 6 :00 A :M and 24 Hours. 

MANUAL CONTROL 

: In spite of the automatic operating mode, and independently, the I-53 module allows at 

any time to establish a manual connection for hours and others. To activate this operation you have to maintain 
pressed the button corresponding to the manual control.

TO ACTIVATE BOTH OUTPUTS AT THE SAME TIME 

: The circuit allows to activate both relay at the same time using 

manual or automatic connections. To activate this option, you have to place the switch INT-3 in ON position. If 
you wish a separate activation for hours and others, you have to place the switch in OFF position.

OPERATING TIME 

:  The module, as we have previously explicated, offer two different 

impulses. The I-53 module incorporates a selector to configure it in continuous hours during 
24 hours, or daily hours (only during the day) with two time margins to select. 
Seeing the drawing Nº1, the selector is indicated as INT-2 and you could find 2 switches.
The switch Nº

1

Module Front Panel

Down

Up

Manual Control

Hours

Minutes

Hour Adjustment

LD1

Enter

H

Q’

1

ON

2

INT-2

1

ON

2

INT-1

Fig. 1

1

ON

2

INT-2

8 - 22 H.

1

ON

2

INT-2

Daily Mode

1

ON

2

INT-2

24 H. Mode.

Daily Mode.

1

ON

2

INT-2

Daily 24H/ Mode

Manual Control

H

Q’

Others

Hours

INT-3

Independent Outputs

1

ON

INT-3

Joint Outputs

1

ON

E L E C T R O N I C C I R C U I T S

 

1

ON

2

INT-1

0.5 sec.

1 sec.

1

ON

2

INT-1

Hours Timming

1

ON

2

INT-1

0.5 sec.

1 sec.

1

ON

2

INT-1

Others Timming.

6 - 24 H.

Summary of Contents for I-53

Page 1: ...tive terminal indicated in the wiring map then connect also the negative of the power supply to the negative terminal indicated in the circuit Verify that the assembly has been correctly done OPERATING The I 53 module is an automatism to imitate the operating Bell clock indicating hours and others Then the hour relay will be activated each hour and the second relay will be activated each 15 minute...

Page 2: ...ween 8 00 A M and 22 P M If you place it in ON position the margin will established between 6 00 A M and 24 Hours MANUAL CONTROL In spite of the automatic operating mode and independently the I 53 module allows at any time to establish a manual connection for hours and others To activate this operation you have to maintain pressed the button corresponding to the manual control TO ACTIVATE BOTH OUT...

Page 3: ...iously damage the module and cancel the module s guarantee Please proceed as followingÊ To obtain a relay output generating a minute signal you have to find a 12 V relay and a 1 N4148 diode Seeing the following electrical and physics maps you have to connect C terminal of the JP1 jumper with the indicated point Do the same operation with the E terminal Connect negative and positive terminals to th...

Page 4: ...ly cancelled GENERAL WIRING MAP R203 C 2 3 V BATERY 1 ON 2 1 ON 2 Others Relay Hours Relay INT 3 Battery JP1 C E INT 2 INT 1 1 ON OUTPUTS CONNECTION LOAD 230 V AC CONNECTION 12 V DC CONNECTION 12 V DC Common Common NO Normally Open NO Normally Open NC Normally Closed NC Normally Closed Device Load Device Load 230 V AC DO NOT FORGET When the circuit works and according to the load you could note a ...

Reviews: