4
HOW TO REMOVE THE BATTERY.
REMOVE AND SUGGESTIONS REGARDING BATTERY.
When the mdoule is not supplied, the module maintains
timing thanks to the battery. The hour display is cancelled till the module is again normally supplied; then the
hour and the rest of the others functions will be activated again.
With the time and according to the number and duration of situations in which
the module was not supplied, the battery will be discharged. In this case, the
module could not recuperate the hour and you have to remove the battery.
The required battery is a 3 V CR-2032 battery, and you could purchase it to your
distributor.
When you will substituate it, be careful in respecting the corresponding polarity.
See the schedule. Do not remove the battery if the module’s power supply is
connected, neither hardly handle it.
C
20
R
32
3
V
.
B
T
RY
A
E
Battery
All the module’s CEBEK have
3 years of total warranty
in thecnical
repairing, and spares from the date of buy.
CEBEK is trade make of FADISEL S.L. more than 300 module’s are avaible in
stock for any purpose
request our CATALOGUE,
or visit our Web.
Http://www.cebek.com
TECHNICAL CONSULTATIONS.
If you have any doubt, you could contact your wholesaler or our Technical Department.
- Via E-Mail,
by mail
P.O Box 23455 - 08080 BARCELONA - SPAIN.
-
Keep the invoice of this module
. For any repair, the corresponding invoice had to be added. If the invoice is
not presented together with this module, the module’s warranty will be automatically cancelled.
GENERAL WIRING MAP.
3
C
R2
0
2
3
V.
BA
TE
RY
Batter y
JP1
Module
CD-34
Power Supply
230 V. AC. Mains
Mains
Switch
250 mA.
Fuse
Apparatus o Machine
to be controlled
by the CD-34
Led
Module
FE-71
TRANSFORMER.
FE-71
0
0
12
230
COUNTERS
CD-34
CD-34
Ref. Full9813
CD-34
CD-34
OPERATING.
HOURS CONTROLLER.
3
JP1
Desold to show
stored registers.
Lateral View of the JP1 Jumper
converted on P1, P2 and P3 buttons.
It is very important to take in account two basic aspects : Firstly module will record data from the present month,
erasing them each new month. For this reason, if you have to note monthly data, you have to write them at the
latest time the last day of the month. The second aspect is the accurate displayed data. Thanks to the calcul of
time averages, etc... The module could display as amaximum an error of minutes. Each button is used to have
access to different registers and thanks to the LD2 led, you could know which is the register :
P3.
Press the P3 button till the LD2 led will light on. On the display you could read the total number of the real
hours that the mdoule had operated, independently if the module had been connected some instants each
day or the quantity of days, this register add and show total hours and minutes concerning the connection
apparatus from the beginning till the date. If you press again on the P3 button, the LD2 led will light on an
intermitten mode, indicating thatthe displayed register correspond to the starting date (the last time that the Start
button had been activated). If you press again, the display will show the third and last register for the P3 button.
The LD2 led will light off and display show the register corresponding to the starting hour (the last time that the Start
button had been activated). If youpress again on the P3 button, the module will display these three register on a
cyclic mode.
P2.
The P2 button show 2 registers. If youpress a first time, the LD2 led will light on, indicating that the displayed
register correspond to the total number of operating days for the controlled apparatus or device. Then, the
module will add all days of the month, in which the apparatus had been connected, independently if the
apparatus had been connected several hours or one minute during the day. If the apparatus has not been
connected one day, this day is not taking in account.
If you press again on the P2 button, the module willshow the last register. The LD2 led will intermittently light and
the display will show the average of worked hours per day. If you press again several times on the P2 button, the
module will display these two registers according to a cyclic mode.
HOW TO HAVE A FAST ACCESS TO CD-34’S REGISTERS.
Frontal del Módulo
Hours/Days
Minutes/Months
Seconds/Years
LD1
LD2
P1
P1
P2
P3
P2
P3
1st pulsation.
LD2 light on.
Time for “ today ” corresponding to the apparatus’operating time.
2sd pulsation.
LD2 intermittent. Time for “ this week” corresponding to the apparatus’operating
1st pulsation.
LD2 light on.
Number of days corresponding to the appartus’ connection.
2sd pulsation.
LD2 intermittent. Hours average done per day.
1st pulsation.
LD2 light on.
Number of Total operating Hours.
2sd pulsation.
LD2 intermittent. Starting Date.
HOW TO CONNECT THE MODULE AND THE APPARATUS TO CONTROL.
To allow the CD-34 to control a
determinated apparatus, you have to install it in parallel. Then, supplying or not the apparatus , you could also
supply or not the CD-34. See the schedule.
Y
S
E R
A
E L E C T R O N I C C I R C U I T S