12. Steps for replacing the filters
A. REPLACEMENT OF SEDIMENT, ACTIVATED CARBON FILTERS AND RE-MINERALISATION POST FILTER
B. SUSTITUTION OF MEMBRANES
1. OPEN THE EQUIPMENT:
open
the lid of the equipment by pressing
the side clips. On raising the lid, be
careful with the LED panel and in
the event that this comes off, put it
back in its position on the front of
the base.
2.ADISCONNECTION OF FILTERS:
disconnect the pipes of the fil
-
ter to be changed by pressing the
quick-released clip, and undo all the
connections between the filter and
the valve.
2.B SUBSTITUTION OF FILTERS
CARTRIDGES:
effect all the connec-
tions between the new filter and the
valve just as they were.
5. CLOSING:
replace the lid and secu-
re it with the side clips, verifying that
the LED panel is properly in place.
3.A DISCONNECTION MEMBRA-
NE-HOLDER:
disconnect the pipes
of the membrane-holder by pressing
the quick-release clip and opening
the membrane-holder with its key.
3.B SUBSTITUTION OF MEMBRA-
NES:
substitute the new membrane
by placing it in the same position
and close the membrane-holder.
4:
put the new filter or membra
-
ne-holder back in the original posi-
tion and connect the pipes, making
sure they are held in place by the
quick-release clip.