11 – Warranty Terms 

 

 Attention!! 

 

The present handbook  is merely indicative, and it is subject to changes in any moment, without giving any notice. 
 
The not respecting strictly the indication found on this handbook, the opening and tampering the product, the incorrect use, the wrong wiring, 
the using of spare parts or optional not original  CEAM Control Equipment, the removing of the labels, of the identification marks put by CEAM 
Control  Equipment,  and  the  hidden  export  to  Extra  CE  counties,  they  make  immediately  lose  the  responsibility  over  the  product  and  the 
warranty right!   
 

WARRANY TERMS: 

 

 the product is under warranty for a period of 12 Months (Art. 1490 C.C.  and following) starting by the delivery note 

date,  also  in  case  it  is  in  vision,  and  then  transformed  in  selling,  the  complete  text  of  the  warranty  conditions  offered  by  CEAM  Control 
Equipment in conformity to the actual laws, are published, and are at disposal of any people which demand for them, the document is registered 
both in paper form and in electronic form, to the CEAM Control Equipment, headquarter,  and to see it, it is sufficient to make a written request, 
specifying the title of the applicant. 

 

The warrany cover: 

The products and the components which bad functioning is referable for sure to production defects, the eventual defect met 
gives only the right to repair it, and not to substitute the product, besides the eventual production defect, does not give any 
right to resolute the contract, or to suspend the payment if not expressly agreed in written by  CEAM. 
 

The warranty does not cover:  

Defects generated by incorrect or improper use of the product 
Defects generated by using spare parts or consumables products not original CEAM 
Defects generated by environmental and/or atmospheric problems and/or natural calamity     
Products and/or services tampered or modified even partially  
Products and/or services to which have been taken off, or tampered,  even partially, labels and lot codes original  CEAM 

 

In any case, the warranty does not cover: 

Batteries, magnetic devices, perishable products and/or consumable products  
The components of Third parts, to which  it must answer directly, the assistance service of the same, with the modalities provided from them. 
The technical time used to verify and/or to repair the products 
The travelling allowance, and the technical intervention on the place, if effected.     
The packaging and shipping cost of the products there and back.   
All the additional costs supported by  CEAM to fulfil the warranty. 

 

Clause of responsibility exclusion 

CEAM  does  not  assume  any  responsibility,  regarding  eventual  damages,  direct  or  in  direct,  caused  to  people  or  things,  or  damages  for  non 
production and/or incorrect production and/or eventual damage, in some way referable to the product and/or to this handbook service.  
 
CEAM  does  not  assume any responsibility regarding  eventual  damages caused  to people  or things because of the eventual not conformity  to 
the product and/or service of the present handbook, which is merely indicative, and that can be changed by CEAM in any moment without giving 
any notice.    

 

 

 

 

   

 

 

 

 

Summary of Contents for IF324

Page 1: ... measurement No contact with Thermocouple Type K IR Range 50 0 1600 0 C Range T C Tipo K 50 0 1370 C With a double Laser Pointer USB Gate Software Ms Windows Art 5A808 Operating Manual Cod IF324_5A808_UK_M1 English Language Product Rev 1 0 Manual Rev 1 2 ...

Page 2: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 2 ...

Page 3: ...rd 5 1 Instrument General Functions 5 2 MODE Key Functionality 5 3 LOG Functionality Data Logger 6 Measurement Procedure 6 1 Instrument Switching On 6 2 Warning SCAN Measurement Activated 6 3 Warning HOLD Measurement NOT Activated 6 4 Automatic Switching Off Function Power Saving 6 5 Important Consideration about the Measures 7 Battery Changing 7 1 Indication Low Battery 7 2 Battery place Opening ...

Page 4: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 4 ...

Page 5: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 5 ...

Page 6: ...m the Spot will have a diameter of 100 mm Fig 1 and at the distance of 12 meters the spot will have a diameter of 1 meter of course this ratio is true also for intermeddle or superior measures to the mentioned values Laser Pointer The Laser ray is used only to simplify the measurement pointing allowing identifying with precision the exact point where the operator is making the measurement and it i...

Page 7: ...surfaces which could the ray in an uncontrolled way Never point the Laser ray on gas or inflammable and or explosive liquids You should never exceed the operative limits written on this manual reminding also that a respectable using extend the product s life The product is not hermetic and it cannot stand humidity steams and liquids which could damage both the electronic and the optical side Avoid...

Page 8: ... of the Trigger Energy save Function with Automatic Power OFF Operative Conditions 0 50 C 32 122 F 10 90 UR Stocking Conditions 10 60 C 14 140 F 5 80 UR Power Supply Battery 9V NEDA 1604A IEC 6RL61 or Equivalent Characteristics Measures without Contact Infrared Infrared Measure Range 50 1600 C 58 0 2912 F Optical Ratio 50 1 to the Distance of 50 cm it has a Spot Diameter 1 cm Accuracy Look at Tabl...

Page 9: ...vided by a micro processor able to make complex calculations it converts the radiations in a precise temperature measure Then as it should be clear the instrument act itself as an optical Passive device with a result that the major will be the distance between the instrument and the Target Target Point of Measure and major will be the dimension of the SPOT and vice versa as explained in the below ...

Page 10: ...tact with infrared Table Range Precision for the Measurements without Contact with Infrared Range C Range F Precision Repeatability Display Resolution 50 20 58 68 2 5 C 4 5 F 1 3 C 2 3 F 0 1 1000 1 1000 20 400 68 752 1 0 1 0 C 1 8 F 0 8 0 5 C 0 9 F 400 800 752 1472 1 5 2 0 C 3 6 F 800 1200 1472 2912 2 5 1200 1600 1472 2912 2 5 1 2 1 0 C 1 8 F Rif Conditions Environmental Temp 23 25 C 73 77 F 3 Ins...

Page 11: ... this period the instrument visualize on the display the word SCAN Ref Cap 4 Pos 1 for short this period would be denominated MEASURE HOLD This mode activates itself automatically when you release the trigger Ref Chap 3 Pos 9 after the measurement and if you don t press any key during this time and you did not disable the energy save function the instrument automatically turns off after few second...

Page 12: ...UP DOWN Ref Chap 5 Pos 2 3 Continuing And to the configuration of the parameters in sequence ε EMS Emissivity Set for the infrared measurement LOCK On Off Activation Deactivation Keyboard Lock H HAL On Off Activation Deactivation High temperature Sound Alarm H HAL Set Point Value Set Set Point High temperature Alarm L LAL On Off Activation Deactivation Low temperature Sound Alarm L LAL Set Point S...

Page 13: ...appears the abbreviation LOG Once assured to be in LOG always keeping pressed the trigger pressing repeatedly the key DOWN up to arriving in visualizing the memory cell 0 visualized on the display little in the high side Ref Chap 4 Pos 8 without releasing the trigger press shortly the red key Backlighting Laser Ref Chap 5 Pos 1 the instrument will confirm the erasing with a double sound note and t...

Page 14: ...with a different temperature and outside the body to be measured the result would be in proportion distorted B the measurement infrared sensor needs the environmental temperature compensation which the instrument makes automatically but to obtain reliable measurements it is necessary to allow to the instrument to adapt itself thermally to the environment where it is especially if before it was in ...

Page 15: ...l while if we are measuring irregular bodies the shape of the SPOT will assume irregular shapes as consequence IDEA To have an idea of how it works it is enough to use an electric torch which produces a light cone which besides its dimension Optical Ratio if you position it in a vertical way it will produce a round lighted area besides if you position it in a slanting way the shape of the lighted ...

Page 16: ... specific for the various kinds of materials to be measured Here following it is published a summary table of Emissivity of the most common materials ATTENTION In case you desire to measure with more accuracy all the materials but in particular the most difficult ones or even impossible ones to be measured you can do it with a simple trick in practice it is enough to create some point of measure T...

Page 17: ...battery or the thermocouple probes which are subject to wear Besides also for the side of measure T C but in particular for the side of the IF we suggest to verify the correct calibration at least twice a year using a calibration oven Black Body Grey Body as the ones at disposal among the optional Ref Series C400 C600 a major frequency of verifying it is suggestible in case the level of critical s...

Page 18: ...he software and then connect the thermometer to the USB gate activating before its gate Ref Par 5 3 5 and then follow the eventual request of the system At the end once you install it correctly pressing the Trigger of the thermometer it will be possible to see on the PC the data taken by the thermometer both those with technology IF and those taken by the thermocouples if connected If everything h...

Page 19: ...Digital Thermometer Range 50 380 C Art 5A805 IF322 Handy Infrared Thermometer 50 550 C Art 5A806 IF323 Handy infrared Thermometer 50 1600 C Art 5A807 IF301D Multi purpose Infrared Thermometer Thermocouple Input Range 0 650 IR 0 1700 C T C Accessory Rechargeable NiMh Battery Size 6LR61 Art 0942 Universal Net Battery Charger 230 Vac 50 Hz Art 0943 C430 A Calibration Kiln Black Body Range 50 350 C C4...

Page 20: ...oes not give any right to resolute the contract or to suspend the payment if not expressly agreed in written by CEAM The warranty does not cover Defects generated by incorrect or improper use of the product Defects generated by using spare parts or consumables products not original CEAM Defects generated by environmental and or atmospheric problems and or natural calamity Products and or services ...

Page 21: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 21 ...

Page 22: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 22 ...

Page 23: ...IF324_5A808_UK_M1 Copyright CEAM Group CEAM Control Equipment 23 ...

Page 24: ...ia Val D Orme No 291 50053 Empoli Firenze Italy Tel 39 0571 924082 Fax 39 0571 924505 Skype Name ceam_info Internet Group Web www ceamgroup com Division Web www ceamcontrolequipment it Support Web www ceamsupport it Service E mail General info ceamgroup it Customer Service sales ceamgroup it Local Reseller ...

Reviews: