STAR1M - Mullion Mifare

®  

standalone controller and card reader

INSTALLATION MANUAL

EN

4] OPERATION MODES

Dipswitch

Standalone mode 

(page 13)

Wiegand mode

  

(page 18)

1

OFF

ON

2

OFF

ON

OFF

ON

Change the 

Master card

NORMAL 

 operation

Dipswitch 3 

option 

44-bit

3

OFF

ON

OFF

ON

Shadow mode 

(page 15)

Standard mode 

(page 16)

26-bit

30-bit

4

Not assigned

The different dipswitch positions are used to switch the STAR1M to a  

standalone system or to a Mifare

®

 access reader.

5] WIRING DIAGRAM

C56

C58

C61

1

MM10

4

3

2

1

ON
ON
ON
ON

L7

Q6

Q7

Q8

R77

R78

R79

P1

1

P3

BZ3

C6

C24

C59

-

+

MM1

MM14

CR3

+

-

CR10

CR25

CR26

CR24

MM3

MM15

CR12

CR13

CR15

I1

+

-

+

-

MM16

CR22

P2

-

+

CR19 CR21 CR20

CR28

CR27

CR29

CR11

R70

R67

R68

R64

R69

R65

C68

CR30

Wire 

colors

Wiring table

Standalone mode 

Wiegand mode

Red

12Vdc

12Vdc

Black

0V

0V

Green

/

Data 0

White

/

Data 1

Blue

Normally open

/

Grey

Common 

/

Purple

Normally closed

/

Brown

Request to exit input

Buzzer input 

Yellow

/

Green LED input 

Orange

/

Red LED input 

LEDs on start-up:

- Green (1s)

- Red (1s)

- Blue + BEEP (1s)

LEDs during routine operation:

- Standby: Blue

- When a tag is read: Green or red

To switch operation mode, please reboot the STAR1M.

Summary of Contents for STAR1M

Page 1: ...cdvigroup com 1 STAR1M Mullion Mifare standalone controller and card reader Security to Access www cdvigroup com English EN STAR1M Mullion Mifare Standalone Controller and Card Reader ...

Page 2: ...on Installation recommendations To protect the device from back EMF do not forget to install the varistor across the lock terminals in parallel This product is shipped with a varistor The varistor must be connected directly to the locking system terminals electric strikes electromagnet or lock operated by the device If the device functions with several locking systems each one must be fitted with ...

Page 3: ... access reader 5 WIRING DIAGRAM C56 C58 C61 1 MM10 4 3 2 1 ON ON ON ON L7 6 Q7 8 R78 P1 1 P3 BZ3 C6 C24 C59 MM1 MM14 CR3 CR10 CR25 CR26 CR24 MM3 MM15 CR12 CR13 CR15 I1 MM16 CR22 P2 CR19 CR21 CR20 CR28 CR27 CR29 R70 R68 R69 R65 C68 CR30 Wire colors Wiring table Standalone mode Wiegand mode Red 12Vdc 12Vdc Black 0V 0V Green Data 0 White Data 1 Blue Normally open Grey Common Purple Normally closed Br...

Page 4: ...ng for the Master card to be programmed when powering on for the 1st time 7 STANDALONE MODE Mifare compliant ISO 14443A Mifare classic Programming using the Master card directly on the reader Capacity 1 Master card 300 or 150 user cards according to mode 1 door controller 1 relay output N O N C contact 1A 12Vdc 1 request to exit input Compatible with METAL PVP Mifare badges BV cards ISO Mifare cre...

Page 5: ...e Fail safe 12V DC ADC335 Push button Magnet Strike fail safe Normal operation 1 ON 2 ON 3 ON 4 ON ON OFF Swipe user card Access granted Beep green LED relay activated Access denied Beep red LED Blue LED Position DIP2 to ON The factory setting of the STAR1M is shadow mode For first use please program a master badge see process page 8 ...

Page 6: ...nt the user card or its shadow card Beep LED OFF then back to yellow LED Present again the same card Beep red LED then back to yellow LED Both cards are deleted Blue LED Present the master badge Swipe the master badge or wait 10 seconds Exit programming mode 7 1 Shadow mode In Shadow mode two different badges are programmed for the same user The user gets one of the two badges and the second badge...

Page 7: ...e master badge or wait 10 seconds Exit programming mode Enter programming mode Yellow LED Present the user card Beep LED OFF then back to yellow LED Present again the same card Beep red LED then back to yellow LED Blue LED Delete user cards Present the master badge Swipe the master card or wait 10 seconds Exit programming mode 7 2 Standard mode In Standard Mode only one user badge is programmed fo...

Page 8: ...ock time Enter programming mode Yellow LED Press the push button Each push button press 1 second Blue LED Present the master badge Default value 5 seconds programmable from 01 to 99 seconds 1 ON 2 ON 3 ON 4 ON ON OFF Switch on power supply White Red LED flashing while the memory is deleted Followed by start up sequence Delete all cards reset the reader to the factory default values Switch off powe...

Page 9: ...rmat 8 MIFARE READER WIEGAND MODE OFF 1 ON 2 ON 3 ON 4 ON ON OFF 1 ON 2 ON 3 ON 4 ON ON OFF 1 ON 2 ON 3 ON 4 ON ON 30 bit Wiegand Output 44 bit Wiegand Output 26 bit Wiegand Output Important Switching shadow mode to independent mode all cards are saved but become independant Switching independent mode to shadow mode all cards are erased ...

Page 10: ...N MANUAL EN 8 3 LEDs management in CENTAUR 8 2 LEDs management in ATRIUM GREEN ACCESS GRANTED RED ACCESS DENIED BLUE STANDBY LED STATUS GREEN ACCESS GRANTED RED ACCESS DENIED BLUE STANDBY LED STATUS GREEN LED CONFIGURATION RED LED CONFIGURATION GREEN LED CONFIGURATION RED LED CONFIGURATION ...

Page 11: ...DVI TAIWAN Phone 886 0 42471 2188 www cdvichina cn CDVI SUISSE Phone 41 0 21 882 18 41 www cdvi ch CDVI CHINA Phone 86 0 10 84606132 82 www cdvichina cn CDVI IBÉRICA SPAIN PORTUGAL Phone 34 0 935 390 966 www cdviberica com CDVI ITALIA Phone 39 0321 90 573 www cdvi it CDVI MAROC Phone 212 0 5 22 48 09 40 www cdvi ma CDVI NORDICS SWEDEN DENMARK NORWAY FINLAND Phone 46 0 31 760 19 30 www cdvi se CDVI...

Reviews: