1] PRODUCT PRESENTATION 

- 2-in-1 Mifare Reader :

  - Standalone Access control system
  - Wiegand Mifare

®

 reader mode

- Resin-coated electronics
- Audible and visual feedback
- 3 metre cable (10 wire cable - AWG28)
- Up to 150 cards (shadow mode)
- Up to 300 cards (standard mode)

- 1 Relay output (1A 12V dc)
- 1 Request to exit input

 -25°C à +70°C

STAR1M

 IP54

Dimensions (L x W x D):

 130 x 41 x 28 mm

Technology: 

13.56 MHz

Protocol:

 Mifare

®

 classic, ultralight C

Input voltage:

 12Vdc

Consumption: 

120mA

Wiegand 26/30/44-bit 

(Mifare

® 

reader)

2] REMINDERS AND RECOMMENDATIONS

Recommended cable

10 wire cable (AWG28)

Recommended power supplies

ADC335 and BS60 (in case the reader 

is powered by neither the controller 

nor the reader controller [INTBUSW]).

The power supply must be designed to 

be a limited power supply as defined 

by EN 60950-1.

Environment

When in a humid area or close to the 

sea, we recommend applying varnish to 

the terminals to avoid oxidation.

Installation recommendations

To protect the device from back EMF, do 

not forget to install the varistor across 

the lock terminals (in parallel).

This product is shipped with a 

varistor.

The varistor must be connected directly 

to the locking system terminals (electric 

strikes, electromagnet, or lock) operated 

by the device. If the device functions with 

several locking systems, each one must 

be fitted with a varistor. The varistor limits 

overload produced by the strike coil, known 

as self-effect or back EMF. If you are using 

a shearlock, electromagnet or other type 

of electric lock, we recommend the use of 

dedicated power supply for the lock.

For optimum 

lighting, be 

careful to not 

fold the cable 

inside the 

product. 

3] MOUNTING KIT

Leaktight 

seal

TF 3x30  

Screws

S5  

Plastic anchor 

TORX

®

  

Screwdriver tip

TORX

®

 3x8 

Screws 

Varistor

METALR tag

STAR1M

1

2

2

1

1

1

1

R76,7

R35,4

7

60

30

Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.

This document is the exclusive property of CDVI and it may not be disclosed to others without permission.

31, av du Gal Leclerc

93691 PANTIN CEDEX

F  R  A  N  C  E

Tel : 33(0)148910102

Fax : 33(0)148912121

www.cdvi.com

Plan M1806-VdE
Edition 00
Date 01/10/2009

ECHELLE 1:1

A4V

DES.: A. Broustal

Matière : ...

Tolérance gale :   0.1 Etat de surface : Ra 3,2

A0228015

Badge PP New

plan coté pour dépôt "dessin&modèle"

C.A.: ...

Vol. (mm

3

) : 

Poids (g) : 

 IK09

Frequency band: 13,553 - 13,567 MHz

Maximum power emitted: 42 dBμA/m

We, CDVI, declare that the STAR1M complies with the 2014/53/UE European directive.

 

The full UE declaration is avaiblable on our website www.cdvi.com.

INSTALLATION MANUAL

EN

Thank you for buying our products and for the trust placed in our company

Summary of Contents for STAR1M

Page 1: ...cdvigroup com 1 STAR1M Mullion Mifare standalone controller and card reader Security to Access www cdvigroup com English EN STAR1M Mullion Mifare Standalone Controller and Card Reader ...

Page 2: ...on Installation recommendations To protect the device from back EMF do not forget to install the varistor across the lock terminals in parallel This product is shipped with a varistor The varistor must be connected directly to the locking system terminals electric strikes electromagnet or lock operated by the device If the device functions with several locking systems each one must be fitted with ...

Page 3: ... access reader 5 WIRING DIAGRAM C56 C58 C61 1 MM10 4 3 2 1 ON ON ON ON L7 6 Q7 8 R78 P1 1 P3 BZ3 C6 C24 C59 MM1 MM14 CR3 CR10 CR25 CR26 CR24 MM3 MM15 CR12 CR13 CR15 I1 MM16 CR22 P2 CR19 CR21 CR20 CR28 CR27 CR29 R70 R68 R69 R65 C68 CR30 Wire colors Wiring table Standalone mode Wiegand mode Red 12Vdc 12Vdc Black 0V 0V Green Data 0 White Data 1 Blue Normally open Grey Common Purple Normally closed Br...

Page 4: ...ng for the Master card to be programmed when powering on for the 1st time 7 STANDALONE MODE Mifare compliant ISO 14443A Mifare classic Programming using the Master card directly on the reader Capacity 1 Master card 300 or 150 user cards according to mode 1 door controller 1 relay output N O N C contact 1A 12Vdc 1 request to exit input Compatible with METAL PVP Mifare badges BV cards ISO Mifare cre...

Page 5: ...e Fail safe 12V DC ADC335 Push button Magnet Strike fail safe Normal operation 1 ON 2 ON 3 ON 4 ON ON OFF Swipe user card Access granted Beep green LED relay activated Access denied Beep red LED Blue LED Position DIP2 to ON The factory setting of the STAR1M is shadow mode For first use please program a master badge see process page 8 ...

Page 6: ...nt the user card or its shadow card Beep LED OFF then back to yellow LED Present again the same card Beep red LED then back to yellow LED Both cards are deleted Blue LED Present the master badge Swipe the master badge or wait 10 seconds Exit programming mode 7 1 Shadow mode In Shadow mode two different badges are programmed for the same user The user gets one of the two badges and the second badge...

Page 7: ...e master badge or wait 10 seconds Exit programming mode Enter programming mode Yellow LED Present the user card Beep LED OFF then back to yellow LED Present again the same card Beep red LED then back to yellow LED Blue LED Delete user cards Present the master badge Swipe the master card or wait 10 seconds Exit programming mode 7 2 Standard mode In Standard Mode only one user badge is programmed fo...

Page 8: ...ock time Enter programming mode Yellow LED Press the push button Each push button press 1 second Blue LED Present the master badge Default value 5 seconds programmable from 01 to 99 seconds 1 ON 2 ON 3 ON 4 ON ON OFF Switch on power supply White Red LED flashing while the memory is deleted Followed by start up sequence Delete all cards reset the reader to the factory default values Switch off powe...

Page 9: ...rmat 8 MIFARE READER WIEGAND MODE OFF 1 ON 2 ON 3 ON 4 ON ON OFF 1 ON 2 ON 3 ON 4 ON ON OFF 1 ON 2 ON 3 ON 4 ON ON 30 bit Wiegand Output 44 bit Wiegand Output 26 bit Wiegand Output Important Switching shadow mode to independent mode all cards are saved but become independant Switching independent mode to shadow mode all cards are erased ...

Page 10: ...N MANUAL EN 8 3 LEDs management in CENTAUR 8 2 LEDs management in ATRIUM GREEN ACCESS GRANTED RED ACCESS DENIED BLUE STANDBY LED STATUS GREEN ACCESS GRANTED RED ACCESS DENIED BLUE STANDBY LED STATUS GREEN LED CONFIGURATION RED LED CONFIGURATION GREEN LED CONFIGURATION RED LED CONFIGURATION ...

Page 11: ...DVI TAIWAN Phone 886 0 42471 2188 www cdvichina cn CDVI SUISSE Phone 41 0 21 882 18 41 www cdvi ch CDVI CHINA Phone 86 0 10 84606132 82 www cdvichina cn CDVI IBÉRICA SPAIN PORTUGAL Phone 34 0 935 390 966 www cdviberica com CDVI ITALIA Phone 39 0321 90 573 www cdvi it CDVI MAROC Phone 212 0 5 22 48 09 40 www cdvi ma CDVI NORDICS SWEDEN DENMARK NORWAY FINLAND Phone 46 0 31 760 19 30 www cdvi se CDVI...

Reviews: