A - Wooden door
1
2
1
1
2
2
4] MOUNTING INSTRUCTIONS
Make sure that there are no pieces missing in the mounting kit. Get the right
tools according to the installation type (Drill, screw drivers, metre tape,...)
and follow the mounting instructions of the SHL1200.
Test the functioning of the
armature plate and the back
plate, then fix the magnet to the
door (note that the mounting
screws are not included).
A - Wooden door
Make a cut on the door leaf
and a cut on the door jamb
in order to insert the magnet
and the armature plate of
the SHL1200 magnet. Then
mark the mounting holes of
the mounting screws. Drill
the mounting holes of the
magnet and of the armature
plate in order to facilitate the
screwing. Drill the cable access
hole.
Insert the cable of the magnet.
Loosen the screws on the side of
the armature plate (1) with the
Allen key. Temporarily mount
the SHL1200. Then adjust the
gap between the magnet and the
armature plate by adjusting the
top screws on the armature, allow
2mm distance maximum. Tighten
the 2 screws on the side of the
armature plate (2) once the test on
the magnet has been successfull.
1
2
(x8)
3
1
2
(x8)
1
1
2
(x8)
2
B - Flush mounting
Place the magnet on the back
plate of the surface housing
as well as the armature on the
second back plate of the surface
housing and fix the magnet on
the door.
Make a cut on the door leaf
and a cut on the door jamb
in order to insert the magnet
and the armature plate of
the SHL1200 magnet. Then
mark the mounting holes of
the mounting screws and drill
the mounting holes of the
magnet and of the armature
plate in order to facilitate the
screwing.
Mount the back plate of the
housing (note that the screws are
not included). Loosen the screws
on the side of the armature plate
(1) with the Allen key. Temporarily
mount the SHL1200. Then adjust
the gap between the magnet and
the armature plate by adjusting
the top screws on the armature,
allow 2mm distance maximum.
Tighten the 2 screws on the side
of the armature plate (2) once
the test on the magnet has been