Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985
The installer’s choice
www.erone.com - www.cdvigroup.com
9
Menu Add
(*) NOTE
: The first TX added acts as Master: that means that it can be used to add more tx using the PLUS option.
The submenu Add Master allows to assign the Master property to any other TX already in memory even not memorized on the first position.
Once a TX has been assigned as Master, its property cannot be removed unless to delete it from the memory using the Delete menu.
The transmitters «Master» are identified with the «#» in the list.
Push TX
Button
Enter the number
of TX [1 < n < 500]
Press the transmitter buttons
which activate Relay 1 and
press P1 to confirm
Example: Relay 1 of the full block
will be activated by buttons A
and C
Push Button of the TX
to store as Master (*)
Push Button
of the first TX
Block memorization
10
Menu Config
Allows to set the operating mode of each relay as Pulse, Step,Timed or ON/OFF In case of Timed it’s possible to set the delay time from 1 sec.
to 24h: 59 min.
PULSE
: the relay stays excited as long as the transmitter is
activated.
ON-OFF
: the relay excites if it is pressed the button A of the
TX and releases when it is pressed the button B. It is enough to
memorize only the button A : the button B automatically releases
the relay.
If the transmitter is a 4-button type, it’s possible to get A=ON ,
B=OFF and C=ON, D=OFF memorizing only the buttons A and C.
WARNING
:
if you memorize only the buttons B or D the function
ON-OFF doesn’t work
STEP
: the relay excites at the first transmission and releases at
the next transmission of the same button of the remote control.
TIMED
: the relay excites at the first transmission and releases
after the delay programmed. Set the desired delay time using P2
to scroll the digits and P1 to confirm and shift to next : the time is