CDVI ROFU BKC-5000B Instructions Manual Download Page 2

Copyright All Rights Reserved ROFU Security International Corp. ROFU BKC-5000B. Published: February 12, 2020

BKC-5000B Pre-Installation

LED & Audible Indicators

BKC-5000B Wiring Diagram

2

Parts List:

Flat head phillips screws,

Cone point

Three-point screwdriver

(special tool)

Anchor bolts x4

Proximity key fob x1

Proximity EM cards x2

Crimp connectors x12

Three-point security screw x1

x4

x1

(BKC-5000B have same wiring and pin setting)

Power on, Standby mode
Unlocked, Door always unlocked
Invalid access, Door always locked

Blue
Green
Red

1 Short beep
1 Long beep
2 Short beeps
3 Short beeps

Constant beeping

Key press
Valid access, Reset is completed
Login completed
Invalid access, Forget to press #

after entering passcode within

30 seconds
Bluetooth device vandalized,

Door sensor is on

LED

Status

Audible Beeps

Status

Reset Procedures

1. Power off Access Control Reader.

2. Move the Pin Jumper to P2 and P3, then power on.

3. Hear a long beep to complete resetting procedures.

4. Move the Pin Jumper back to P1 and P2 to Normal setting.

5. Login as Admin and check all users, audit trail events are all cleared and everything is reset to

    factory default setting, except device name.

RTE (Request-To-Exit)
RTE (Request-To-Exit)
DS (Door Sensor)
DS (Door Sensor)
NC (Fail-Safe Electrified Lock)
COM
NO (Fail-Secure Electrified Lock)
V- (Power Supply)
V+ (Power Supply)
ALM (Alarm Output)
ALM (Alarm Output)

(Polarity

Insensitive)

Green
Green
Brown
Brown
Yellow
White
Blue
Black
Red
Orange
Orange

Cable

Normal

Buzzer

Jumper Pin Setting:

Reset

(Default)

Summary of Contents for ROFU BKC-5000B

Page 1: ...larm has been triggered Overhead LEDs and Backlit keys for easy use in the dark Wrong code lockout if an incorrect passcode is entered 3 times in a row the keypad will lock down for 60 seconds Specifi...

Page 2: ...leted Invalid access Forget to press after entering passcode within 30 seconds Bluetooth device vandalized Door sensor is on LED Status Audible Beeps Status Reset Procedures 1 Power off Access Control...

Page 3: ...plice Crimp connectors BKC 5000B Keypads Installation Template Flat head phillips screws Three point security screw Anchor bolts System wiring Open BKC 5000B Keypad by loosening and removing the back...

Page 4: ...ator Note 1 Administrator ID ADMIN can not be changed We recommend changing Admin s default passcode 12345 right after you login as the admin Go to setting page tap Admin Passcode to edit Admin Passco...

Page 5: ...fault passcode It s important to change your Admin passcode Immediately You can enable Door Sensor when you connect to a closed circuit magnetic sensor or a monitored door lock that has door sensor or...

Page 6: ...its Tap user CARD FOB to enter assigned 10 digits code printed in card fob Keypad and Card Fob Access can be independently enabled disabled for a user Tap Access Types to choose Permanent Temporary Nu...

Page 7: ...Back to the main page Tap Auto to enable Auto unlock function to access Figure Tap to go to Device List page as Figure Select the desired Bluetooth Access Control Keypads Readers around you Tap Setti...

Page 8: ...meters 164ft distance The response time of Bluetooth signal may vary depending on mobile device Add Proximity Card Fob to A User by Reading the Card on The Keypad Add card fob numbers to the ADMIN Ad...

Reviews: