14
15
EN
EN
IPV
IP Video Door Station
EN
Door
Door
Station
Station
Backbox
Backbox
Varistor
Varistor
CDVI screws
CDVI screws
M5X20
M5X20
CDVI adaptor
CDVI adaptor
Installation
Installation
manual
manual
11
11
11
44
11
11
3] MOUNTING KIT
1] PRODUCT INTRODUCTION
2] REMINDERS AND RECOMMENDATIONS
In standby mode, the electric strike is not powered and the door is locked. When the relay
is activated with the BP through the “open the door” function on the monitor/smartphone,
the strike is then powered and the door opens (fail safe locking).
The IPV1 door station must connect to the IP network with an RJ45 CAT5e cable
(Ethernet).
The door station has 2 relays NO/NC, and 2 exit push buttons (RTE).
You will need a computer just for the initial configuration and set-up.
Don’t forget to select secret questions in My Account, as they will allow users to
recover their password if necessary.
The DIGIP Call range of door stations allows users to receive calls from visitors, see and
talk to them, and remotely open the door.
Calls are answered from a monitor mounted on a wall (or desktop mount), a smartphone,
or a computer.
To configure the calls from a smartphone, please download the app DIGIP Call (available
for both iOS and Android).
Once downloaded, you will need to create an account on our cloud server.
The audio and video feed between the door station and the user is transmitted via:
• Internet IP network
• Intranet IP network
The IPV door station is easy to install, with minimal cabling requirements. The door station
connects to:
• A 12V power supply (recommended CDVI product: ADC335)
• IP network (CAT5e or Wifi)
• A strike or maglock (2 available relays)
Input voltage: 12Vdc (power supply ADC335 optional) or PoE
Consumption: 400mA
Thank you for buying our products and for the confidence you have placed in our company.
120
250
85
215
62,5
60,5
235
60
205
15
20
20
15
100
Cuve
Façade
Joint
Eclairage
Camera
Afficheur
Haut-parleur
Bouton
Micro
85
120
250
215
Weight (g) :
Vol. (mm
3) :
Platine IPV1
Surface condition: Ra 3,2
General tolerance: 0.2
Material : ...
DWG: W.Sainvil
A3H
SCALE 1:5
Date 03/04/2019
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax : 33(0)148912121
www.cdvi.com
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
25
4,90
1/4" (6,35mm)
Ce document est la propritété exclusive de CDVI, il ne peut être communiqué à des tiers sans son autorisation.
This document is the exclusive property of CDVI and it may not be disclosed to others without permission.
31, av du Gal Leclerc
93691 PANTIN CEDEX
F R A N C E
Tel : 33(0)148910102
Fax : 33(0)148912121
www.cdvi.com
Plan M1540
Edition 02
Date 22/01/2009
ECHELLE 2:1
A4V
DES.: A. Broustal
ODIAX-2
Outil Tournevis - Screwdriver Tool
Acier trempé (clair) - Tempered steel
CA: V0701000005ED2
Vol. (mm
3
) : 649.06
Poids (g) : 5.19
IP64
-20°C to +70°C
IK9