7] TYPICAL INSTALLATION WITH WIEGAND BUS INTERFACE (INTBUSW)
- Use AC or DC power supply.
- The mawimum distance between
the reader interface and the
controller unit is 50 meters.
- DGM1D time lock is programmable
from 2 to 20 seconds with the
PCV123D handheld terminal.
- If using the DGM1D with the reader
interface (INTBUSDGM1), make
sure JP2 jumper is ON.
- Wiegand format must be the same
Between door controller (INTBUSW)
and bus interface (INTW DGM1D)
(Wiegand 26 or 44 bits).
IMPORTANT RECOMMENDATIONS
EM Input
(Door status)
Wire
shielded
SYT1wire
shielded
Strike
Magnetic lock
Varistor
To th next reader
controller
Without jumper
without clock
With jumper
with clock
Without
jumper
26 Bits
With jumper
44 bits
Standalone or
integrated mode
(Refer to
INTBUSW
manual)
12 V DC only
(Default configuration)
Cut the strap
12 V AC or 24 V DC
INTBUSW
INTWDGM1
Reader format must be
Identical to controller
format INTBUSW
SYT1 wire
1 pair 8/10ème
SYT1 wire
1 pair 8/10ème