DGM1D
1-Door Mifare
®
controller/reader system
INSTALLATION MANUAL
EN
16
cdviberica.com
cdvigroup.com
6] TYPICAL INSTALLATION WITH BUS INTERFACE (INTBUSDGM1D)
Recommended cable:
AWG35 2 pair shielded cable.
Use 1 pair cable to power the controller and
another pair for the data transmission.
DGM1D
Reader
Wire SYT1 8/10e mm
2
4 core cable
shield or coaxial (Depend on distance)
- Use AC or DC power supply.
- The mawimum distance between
the reader interface and the controller
unit is 50 meters.
- DGM1D time lock is programmable
from 2 to 20 seconds with the
PCV123D handheld terminal.
- If using the DGM1D with the reader
interface (INTBUSDGM1), make sure JP2
jumper is ON.
RED
GREEN
IMPORTANT
RECOMMENDATIONS
DGM1D
Terminals
Description
J2
1
ANT
Antenna
2
GND
Antenna
3
Led R
Red LED
4
Led V
Green LED
J1
1
B
BUS RS 485
2
A
BUS RS 485
3
TX
PCV123D Link
4
RX
PCV123D Link
5
GND
PCV123D Link
J5
1
DATAS
Data
2
GND
Request to exit input (Push button)
3
GND
Ground
4
BP
Request to exit input (Push button)
J3
1
NO
N.O. relay output
2
C
Common relay output
3
NC
NC relay output
4
12
Input voltage 12V AC/DC
5
V
Input voltage 12V AC/DC