background image

4

5

EN

EN

CZ3000

Self-aligning Magnetic Shearlock

+

_

NC
CO
MN
O

12VDC

24VDC

(x2)

1

2

(x8)

3

(x2)

1

2

(x8)

1

(x2)

1

2

(x8)

2

5] WIRING DIAGRAM

* Input voltage: 12 VDC or 24 VDC

  The magnet can be powered in 12 VDC

  or in 24 VDC according to the jumper

 settings.

Terminal block

 +

 

Input voltage 12 V or 24 VDC*

 -

 

Input voltage 12 V or 24VDC*

 NC

 

Normally closed contact

 

C

 Common

 NO

 

Normally open contact

C - Surface mount (Optional: KCZ3000 kit)

Fix the magnet on the door and 

place the housings.

Measure and mark the center 

lines to determine the magnet 

position on the jamb and the 

armature plate on the door 

leaf frame. Then drill the fixing 

screw  holes  to  fix  the  screws 

easily.

Important: The surface hou-

sing can be mounted in horizon-

tal or in vertical in the secure 

side.

Mount the brackets of the housing 

on the jamb and on the door leaf. 

Insert the cable and temporarily 

fix  the  magnet  and  the  armature 

plate to the bracket of the hou-

sing. Loosen the screws on the 

side of the armature plate (1) with 

the Allen key. Then adjust the 

gap between the magnet and the 

armature plate by adjusting the 

top screws on the armature, allow 

2mm distance maximum. Tighten 

the 2 screws on the side of the ar-

mature plate (2) once the test on 

the magnet has been successfull.

Summary of Contents for CZ3000

Page 1: ...FR EN 10 WARRANTY YEAR Self aligning Magnetic Shearlock Ventouse cisaillement et auto alignement CZ3000...

Page 2: ...is a Shear maglock with a patented self aligning mechanism This magnet is mortice and monitored as stan dard and can be surface mounted Surface housing kit The maglock can be mounted on any type of do...

Page 3: ...e surface housing and fix the magnet on the door Cut the holes on the door leaf and on the door jamb in order to insert the magnet and the arma ture plate of the CZ3000 magnet Then mark the mounting h...

Page 4: ...osition on the jamb and the armature plate on the door leaf frame Then drill the fixing screw holes to fix the screws easily Important The surface hou sing can be mounted in horizon tal or in vertical...

Page 5: ...ition Varistance int gr e Finition aluminium acier Alimentation 12 ou 24 V DC Consommation 12 V DC 450 mA 24 V DC 225 mA 3 KIT DE MONTAGE 3 KIT DE MONTAGE 2 RAPPELS ET RECOMMANDATIONS Rappel de c blag...

Page 6: ...e 1 Puis avec une cl 6 pans ajuster la contre plaque 2 mm de la ven touse Ress rer ensuite les 2 crous de blocage 2 Testez le fonctionnement de la ven touse et de la contre plaque puis fixez les atten...

Page 7: ...contre plaque sur l ouvrant puis percez la surface pour faciliter le vissage Important le kit de mise en saillie doit se poser en horizontal ou en vertical sur une porte s ou vrant vers l int rieur Fa...

Page 8: ...DVI BENELUX BELGIUM NETHERLANDS LUXEMBOURG 32 0 56 73 93 00 www cdvibenelux com CDVI TAIWAN 886 0 42471 2188 www cdvichina cn CDVI SUISSE 41 0 21 882 18 41 www cdvi ch CDVI CHINA 86 0 10 84606132 82 w...