Using the CA-A370 provides higher network isolation from noise, thus greatly increasing communications

 

 

reliability. The CA-A370 simplifies installation, and makes running an RS-485 network more cost-effective  

 

 

by reducing wiring and installation time.

 

RELAY EXPANSION MODULE (CA-A460)

 

 

The Model CA-A460 Relay Expansion module provides an additional seven relays to a CT-V900 controller.

 

 

Up to 2 Plug and Play relay expansion modules can be added to each controller for a total of 16 relays per

 

 

controller. The relay expansion modules are connected to the controller via an RS-485 E-bus, allowing you to

 

 

install the relay modules a maximum distance of 1220m/4000ft. from the controller. The module features an

 

 

activation status LED for each relay, a communication failure LED with an associated output, a 24-hour

 

 

tamper input and supply monitoring. Removable terminals are optional.

 

ELEVATOR FLOOR CONTROLLER (CA-A480)

 

 

Connected to the controller’s expansion bus, the CA-A480 can control up to 16 floors. Each of the CA-A480

 

 

floor  control  relays  can  be  interfaced  directly  with  an  elevator’s  floor  control  buttons  in  2  modes  (Non

 

 

Destination Controlled and Destination Controlled). When using the Non Destination Controlled Mode and a

 

 

valid card is presented, the appropriate floor control relays will become enabled allowing the card holder to

 

 

select the desired floor. The Destination Controlled Mode offers a far superior event trail and user accountability

 

 

by permitting the card holder to make only one floor selection upon presentation of their card. In this mode an

 

 

event is logged indicating the selected floor. In addition to these advanced floor and elevator control features,

 

 

the CA-A480 also features full supervision, backup battery and a fire alarm input.

 

LOCK CONTROL MODULE (CA-A110)

 

 

The CA-A110 Lock Control Module has been designed to greatly reduce installation time and simplify the

 

 

connection of electromagnetic locks when used alone or in conjunction with door strikes. The CA-A110 

 

 

Lock Control Module consists of two on-board, heavy duty 12V relays, two inputs for fire alarm contacts

 

 

 

and two relay activation LED indicators. The relays, which are used to control power to the electromagnetic  

 

 

locks, are toggled by the activation of the controller’s lock output terminals or the CA-A110’s fire alarm

 

 

 

contact inputs.

 

TRACKER LCD KEYPAD (CK-TRAK-L)

 

 

The Tracker LCD Keypad serves as a display unit for your Tracker Time and Attendance Software. The

 

 

keypad’s buttons do not perform any actions. When an access card is presented to a reader assigned to

 

 

Tracker, the keypad will display the card number as well as a confirmation of a valid punch in or punch out.

 

 

When used with Anti-passback applications, the keypad will also display an error if the card user has already

 

 

 punched in or out.

CT-V900 CONTROLLER 

5

www.cdvgroup.com

Summary of Contents for CT-V900

Page 1: ...CT V900 Controller Installation Manual...

Page 2: ......

Page 3: ...kup 7 LED Indicators 7 Upon Power Up 7 Battery Indications 7 Jumper Settings 8 BATT ON OFF 8 EOL Controller Network 8 12V 24V Lock 1 8 12V 24V Lock 2 9 High Low Network Impedance 9 EOL E Bus Network 9...

Page 4: ...our web site at www postech ca ACCESSORY MODULES POSIPROX CARD READER CR R880 Proximity technology will never be the same again PosiProx sets exacting new standards in design reliability and affordabi...

Page 5: ...allowing the card holder to selectthedesiredfloor TheDestinationControlledModeoffersafarsuperioreventtrailanduseraccountability by permitting the card holder to make only one floor selection upon pre...

Page 6: ...m 2 5 wide 10cm 4 deep Multiple Conduit Knock outs Two 25mm 1 or 31mm 1 25 and one 12mm 0 5 or 19mm 0 75 on each side Minimum Clearance For Cabinet 25cm 10 clear space around all sides 38cm 15 clear s...

Page 7: ...strobe during this one minute period LED INDICATORS For location of LEDs refer to Figure 2 on page 8 UPON POWER UP The AC PRESENT LED should be on The READER 5 VOLT LED should be on The 12 VOLT SUPPL...

Page 8: ...er to off until the the battery is replaced Note however if a complete power loss occurs the time and date as well as all controller programming will be lost EOL CONTROLLER NETWORK Places the EOL term...

Page 9: ...ntrollers each Using Table 1 on page 10 set the dip switches to the desired controller address Each of these loops is assigned to a specific COM port Controllers connected to the selected COM port wil...

Page 10: ...F OFF OFF ON OFF OFF 31 OFF ON ON ON ON OFF 53 OFF OFF ON OFF ON ON 10 ON OFF OFF ON OFF OFF 32 ON ON ON ON ON OFF 54 ON OFF ON OFF ON ON 11 OFF ON OFF ON OFF OFF 33 OFF OFF OFF OFF OFF ON 55 OFF ON O...

Page 11: ...CA 360 converter as shown in Figure 5 If the access control server is located less than 25 feet from the first controller you can connect the access control server directly to the controller s RS 232...

Page 12: ...assigned by the dip switches on each controller see page 9 do not have to correspond to the actual order of controller placement along the RS 485 network However we recommend that this is done to faci...

Page 13: ...CT V900 CONTROLLER 13 Figure 9 Overview of Access Control System Using Centaur 3 0 www cdvgroup com...

Page 14: ...free exit Controlled entry and exit by using 2 readers per door no entry or exit registration Controlled entry and exit by using 2 readers and 2 keypads per door no entry or exit registration Reader...

Page 15: ...ts are protected by fuseless technology and will shutdown if the current exceeds 800mA 12 24VDC If you have one door with a reader on each side of the door you can use either lock output You can progr...

Page 16: ...nd wire fault short circuit recognition but will generate an alarm condition when the state of the input is breached Only odd numbered inputs 1 3 5 need to be programmed ATZ 2R CONNECTION 16 INPUTS Th...

Page 17: ...ators 2 Floors per Elevator 64 Schedules per Floor per Elevator Yes Floor Groups 128 Inputs Readers 2 Wiegand or Track 2 Magnetic Swipe Card Readers Keypads 2 Wiegand and or BCD Keypads Multi Purpose...

Page 18: ...nk Distributed Architecture 100 off line operation Local Anti passback Dynamic Memory Adjustment Operates with all Centaur Software Applications E Bus for Plug and Play expansion modules Ethernet or N...

Page 19: ...CT V900 CONTROLLER 19 DIAGRAMS SYSTEM DIAGRAM Figure 14 Overview of Controller Connections www cdvgroup com...

Page 20: ...the door is monitored by installing a magnetic door contact reed switch Separate wire runs must be installed for each card reader door contact and door locking device With this configuration a card a...

Page 21: ...used so that the system can differentiate between a door forced open and an authorized exit The REX can be programmed for free exit according to a specific schedule otherwise a door forced open event...

Page 22: ...wise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Because Seller does not install or connect the products and becaus...

Page 23: ...31 avenue du G n ral Leclerc 93500 PANTIN T l 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 www cdvgroup com...

Reviews: