CDVI CDV96KP User Manual Download Page 17

-15-

Input the master code.
(Default:   [                  ]+[#] )

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+

Beep+

Beep+

Beep

18+#

19+#

21+#

60+#

2011+#

1006+#

2010+#

2012+#

The color of key indicator

Beep, Beep+

 *

(The color 

 of standby)

The color of 

key indicator

 for relay2

(blue-white)

(green)

(green)

(green)

(green)

(green    blue-white)

(green    blue-white)

(green    blue-white)

(green    blue-white)

   15.Temporary

 Code    

     

(Single

 

Use only)

       

  

 

 

Password for relay1

   16.Temporary

 Code 

      

(Singl

Use only)

   

 

   

Password

Enter 

 the setting code. 

Enter

 the setting code. 

Enter

 the setting 

code 

(

ex.:21)

20~59

60~99

   17.Setting the code 

        for user group1

  

      Locations 20 to 59

   18.Setting the code   

       for user group2

     Locations 60 to 99

Enter

 the setting code.

(ex.:60)

Enter the code req

 (ex.: 1006)

1~12 digits

Enter the code req

 (ex.: 2011)

1~12 digits

I

Enter the code req

 (ex.: 2011)

1~12 digits

Enter the code req

 (ex.: 2012)

1~12 digits

- The user code group

 

1 is used to release the first lock

 

and the user 

codegroup

 

2 is used to release the second lock

 

(the second lock 

requires

 external device

 CDV-RLC

 to support

 this function

).

- If the password length exceeds 12 digits, the system will 

emit 4 

beeps eg.

 “beep,beep,beep,beep”,and the digitals you input before will

be cleared at the same time.

- The user code can not be set the same as the master code and

temporary code.

The colo

u

r of key indicator

The colo

u

r of key indicator

The colo

u

r of key indicator

The colo

u

r of key indicator

The colo

u

r of key indicator

The colo

u

r of key indicator

The colo

u

r of key indicator

The colo

u

r of key indicator

- When the correct temporary password

 has been used

 to release 

the door

 

the system will clear the temporary password after 60 

seconds.

 T

he password

 is still

 valid 

for 

60 seconds after

 enteri

ng the

 

correct temporary password

-  Temporary

 

1 is used to release the first lock

 

and temporary

 

2 is 

used to release the second lock

 

(the second lock 

requires

 external 

device 

, CDV-RLC, 

to support

 this function

).

- If the password length exceeds 12 digits, the system will 

emit

 

beeps eg.

 “beep,beep,beep,beep”and the digit

s

 

entered

 beforewill 

be cleared at the same time.

- The temporary code can not be set the same as the master code 

and user code.

When the  “     cancel”  key is pressed, the  indicator will show its standby colo

u

r, the buzzer beeps, and the 

system exits the setting mode.

When there isn’t any operation in 10s, the  indicator will show its standby colo

u

r, the buzzer beeps, and the 

system    exits the setting mode.

When 

setting

 input

 fail

s

, the colo

u

r of key indicator will turn red 

and

 the buzzer 

will 

beep

.

Summary of Contents for CDV96KP

Page 1: ...English User Manual 2 Wire Video Outdoor Station 1 4 5 6 9 8 0 7 2 3 1 4 5 6 9 8 0 7 2 3 CDV96 KP CDV96KP SF CDV ENG 611 F KP V1 190307...

Page 2: ...and Functions 1 2 Terminal Descriptions 2 3 Mounting 2 4 System Wiring and Connections 4 5 Pan tilt Zoom 8 6 Functions Setting Up 9 7 Unlock Operations 17 8 Specifications 17 9 Cables Requirements 18...

Page 3: ...s Mounting box 30 mm 1 4 5 6 9 8 0 7 2 3 1 4 5 6 9 8 0 7 2 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CDV96KP Rain Cover CDV96KP 1 Camera lens 2 Camera LED 3 Speaker 4 Touch keypad 5 Keypad LED 6 Call button 7...

Page 4: ...r connection port L1 L2 Bus line connection no polarity Main Connect Port For connection of the bus line and the electronic locks PL External lock power input CDV96KP Mounting Drill holes in the wall...

Page 5: ...ied to fix the panel Placing Name Label CDV96KP SF Mounting Make a hole in the wall to match the size of the mounting box and fix to the wall Connect the wiring see pg 4 Use a screwdriver to remove th...

Page 6: ...k Connection EB LOCK L1 L2 PL S1 GND Jumper position in 2 3 1 2 3 Door Lock Controlled with Internal Power Note 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door...

Page 7: ...t be used according to the lock power requirements 2 The internal relay contact is restricted to AC or DC 24V 1A 3 The jumper must be removed before connecting Power on to unlock Fail Secure type Unlo...

Page 8: ...2 2 Camera Device Address 1 1 Camera Device Address 0 Basic IN OUT Wiring Mode Device Address 0 BUS IM BUS DS PC6A AC 100 240VAC 1 4 5 6 9 8 0 7 2 3 Code 0 Master Code 00 Slave 2 Code 00 Slave 1 Multi...

Page 9: ...0VAC BUS IM BUS DS PC6A AC 1 4 5 6 9 8 0 7 2 3 Code 00 Master Code 00 Slave 1 Code 00 Slave 2 Code 00 Slave 3 With DBC4A1 Wiring Mode 4 Max IMPORTANT Subject to cable type Please see cable distance ch...

Page 10: ...DX or CDV47MG When an image at a door station is displayed move to the desired position by touching on the screen to view the image in zoom mode If greater detail about visitors is required move to th...

Page 11: ...mode The default setting is as the cancel button and asconfirm button please refer to function 8 setting below for detailed information Sliding a finger to touch the digital keypad may cause erroneou...

Page 12: ...s 0 1 0 102 12 SPK Volume Adjust Valid keys 0 9 4 11 13 Device Address Valid keys 0 3 0 12 14 Night Light Level Valid keys 0 5 4 13 Password for relay1 Temporary Code Single Use only Temporary Code Si...

Page 13: ...With power on and the reset is activated the key illumination will blink and the touching will not operate once complete the key illumination will stop flashing and a long beep will be emitted When t...

Page 14: ...tone is set to 1 pressing the digital keypad will flash one time ex 1 Enter the req Enter the code Enter the code req req range 0 on 1 off Beep Beep Beep Beep ex 1 range 0 normal 1 reverse When set t...

Page 15: ...a call is in progress When in talking mode enter the Master code the LED turns white to activate the volume adjusting function MIC adjustment 1 up 4 down Speaker adjustment 3 up 6 down The colour of k...

Page 16: ...2 device address 2 3 device address 3 Night Light Level 0 5 The higher the number the brighterthe night lights The colour of key indicator The colour of key indicator The colour of key indicator The...

Page 17: ...t before will be cleared at the same time The user code can not be set the same as the master code and temporary code The colour of key indicator The colour of key indicator The colour of key indicato...

Page 18: ...1 range 0 a partment 1 villa Enter the code req ex 1 range Valid keys 0 9 0 apartment multiway 1 villa House When the work mode is villa thecall address 00 or 16 Scene 0 standby blue calling blue blin...

Page 19: ...assword is entered the buzzer will sound of beep beep beep When the registered user code has been entered using the keypad 1 12 digits the LED background indicator lights up the buzzer sounds and the...

Page 20: ...1 mm2 80 80 40 When Monitor quantity 20 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1 5 mm2 70 50 30 9 Cable Requirements The maximum distance of the wiring is limited within the...

Page 21: ...the right adaptor which is supplied by the manufacture or approved by the manufacture Pay attention to the high voltage inside the products please refer service only to a trained and qualified profess...

Page 22: ...Note...

Page 23: ...Note...

Page 24: ...The design and specifications can be modified without notice to the user Right to interpret and copyright of this manual are reserved CDV ENG 611 F KP V1 190307...

Reviews: