![CDVI CDV96KP User Manual Download Page 13](http://html1.mh-extra.com/html/cdvi/cdv96kp/cdv96kp_user-manual_2576928013.webp)
-11-
1
4 5 6
9
8
0 #
7
2 3
*
Input the master code.
(Default: [ ] +[#] )
(blue-white)
The color of key indicator
Beep+, Beep
Beep+, Beep
Beep+, Beep
Beep+, Beep
Beep+, Beep
Beep+
Beep+
Beep+
Beep+
3.Setting the key
illumination time
4.Setting the
unlock time
2.Setting the master code
(Default 1234)
(Default 10s)
(Default 1s)
1.Reset all settings
00+#
1234+#
4321+#
01+#
10+#
09+#
02+#
03+#
(green)
(green)
(green)
(green)
The color of key indicator
The color of key indicator
The color of key indicator
The color of key indicator
(green blue-white)
(green blue-white)
(green blue-white)
(green blue-white)
-
Beep, Beep+
*
Each operation is indicated by the lighting up of the
different color of digital key and nameplate , and by the
sounding of the buzzer.
Enter
the setting code.
Enter
the setting code.
Enter
the setting code.
Enter
the setting code.
Enter the mastercode
Enter the
new master code
(ex.: 4321)(1~12 digits)
Enter the
code
req.
(ex.: 10)
range:00 or 10~99
Enter the
code
req.
(ex.: 09)
range:01~99
When the “ cancel” key is pressed, the indicator will show
the
standby color, the buzzer beeps, and the
system
will
exit the
out of programming mode
.
- All settings will restore to their
default value.
- W
ith
power on
and
the
reset
is activated
,
the key
illumination will blink and the
touching
will not operate
,
once
complete
the key illumination will
stop
flashing
and
a
long beep
will be emitted.
- When there isn’t any operation within 10s, the indicator will show the standby color, the buzzer beeps, and the
system will exit the programming mode
.
-
When
a
setting
input
fail
s
, the color of key indicator will turn red
and
the buzzer
will
beep
.
The
colo
u
r
key indicator
(The colo
u
r
of standby)
- The unlock time can be set
by
both monitor and door station,
the valid value is
always
the
time
last set either at the door station
or monitor.
.
- If the key illumination time is set
to 00,
the key illumination will
be lit
constantly
when
the
power
is
on.
- If the key illumination time is set to
10~99,
the key illumination will light
up for 10~99 seconds.
In
this mode,
the key illumination
switches
off in
standby mode, touching any digital
key
will
illuminate,
this
activation
only turns on the keypad it is not
included with any code used.
.
- The master code
can be
1~12
digits
in length.T
he same code
cannot be setfor both the user
code and themaster code
. I
t is
recommendedthat
the master
code is
changed from
the default
code
.
The colo
u
r of key indicator
The colo
u
r of key indicator
The colo
u
r of key indicator
The colo
u
r of key indicator
Summary of Contents for CDV96KP
Page 22: ...Note...
Page 23: ...Note...