Input the master code.
(Default:   [                  ] +[#] )

(blue-white)

The color of key indicator

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+, Beep

Beep+

Beep+

Beep+

Beep+

   3.Setting the key 

      illumination time

   4.Setting the 

      unlock time

   2.Setting the master code

(Default 1234)

(Default 10s)

(Default 1s)

   1.Reset all settings

00+#

1234+#

4321+#

01+#

10+#

09+#

02+#

03+#

(green)

(green)

(green)

(green)

The color of key indicator

The color of key indicator

The color of key indicator

The color of key indicator

(green    blue-white)

(green    blue-white)

(green    blue-white)

(green    blue-white)

Beep, Beep+

 *

Each operation is indicated by the lighting up of the 
different color of digital key and nameplate , and by the 
sounding of the buzzer.

Enter

 the setting code. 

Enter

 the setting code. 

Enter

 the setting code. 

Enter

 the setting code. 

Enter the mastercode

Enter the

 new master code 

(ex.:  4321)(1~12 digits)

Enter the

 code

 req.

 (ex.: 10)

     

range:00 or 10~99

Enter the

 code

 req.

 (ex.: 09)

         

range:01~99

When the  “     cancel”  key is pressed, the  indicator will show 

the

 standby color, the buzzer beeps, and the 

system

 will

 exit the

 out of programming mode

.

- All settings will restore to their 

default value.

- W

ith

 power on 

and

 

the

 

 reset

 is activated

,

 

the key 

illumination will blink and the

touching 

will not operate

,

once 

complete 

the key illumination will 

stop 

flashing

and 

long beep

 will be emitted.

- When there isn’t any operation within 10s, the  indicator will show the standby color, the buzzer beeps, and the
   

system will exit the programming mode

.

When 

setting

 input

 fail

s

, the color of key indicator will turn red 

and

 the buzzer 

will 

beep

.

The

 

colo

u

r  

key indicator

(The colo

u

 of standby)

- The unlock time can be set 

by

  

both monitor and door station, 

the valid value is 

always 

the 

time 

last set either at the door station 

or monitor.

- If the key illumination time is set 

to 00,

 

the key illumination will

 be lit 

constantly

 when

 the

 power 

is 

on.

- If the key illumination time is set to 

10~99,

 

the key illumination will light 

up for 10~99 seconds.

 In

 this mode,

the key illumination 

switches

 off in 

standby mode, touching any digital 

key 

will

 illuminate,

 

 this

 activation  

only turns on the keypad it is not 
included with any code used.

.

- The master code 

can be

 1~12

digits

 in length.T

he same code 

cannot be setfor both the user 

code and themaster code

. I

t is 

recommendedthat 

the master 

code is

 

changed from

 the default

 

code

 .

The colo

u

r of key indicator

The colo

u

r of key indicator

The colo

u

r of key indicator

The colo

u

r of key indicator

Summary of Contents for CDV96KP

Page 1: ...English User Manual 2 Wire Video Outdoor Station 1 4 5 6 9 8 0 7 2 3 1 4 5 6 9 8 0 7 2 3 CDV96 KP CDV96KP SF CDV ENG 611 F KP V1 190307...

Page 2: ...and Functions 1 2 Terminal Descriptions 2 3 Mounting 2 4 System Wiring and Connections 4 5 Pan tilt Zoom 8 6 Functions Setting Up 9 7 Unlock Operations 17 8 Specifications 17 9 Cables Requirements 18...

Page 3: ...s Mounting box 30 mm 1 4 5 6 9 8 0 7 2 3 1 4 5 6 9 8 0 7 2 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CDV96KP Rain Cover CDV96KP 1 Camera lens 2 Camera LED 3 Speaker 4 Touch keypad 5 Keypad LED 6 Call button 7...

Page 4: ...r connection port L1 L2 Bus line connection no polarity Main Connect Port For connection of the bus line and the electronic locks PL External lock power input CDV96KP Mounting Drill holes in the wall...

Page 5: ...ied to fix the panel Placing Name Label CDV96KP SF Mounting Make a hole in the wall to match the size of the mounting box and fix to the wall Connect the wiring see pg 4 Use a screwdriver to remove th...

Page 6: ...k Connection EB LOCK L1 L2 PL S1 GND Jumper position in 2 3 1 2 3 Door Lock Controlled with Internal Power Note 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door...

Page 7: ...t be used according to the lock power requirements 2 The internal relay contact is restricted to AC or DC 24V 1A 3 The jumper must be removed before connecting Power on to unlock Fail Secure type Unlo...

Page 8: ...2 2 Camera Device Address 1 1 Camera Device Address 0 Basic IN OUT Wiring Mode Device Address 0 BUS IM BUS DS PC6A AC 100 240VAC 1 4 5 6 9 8 0 7 2 3 Code 0 Master Code 00 Slave 2 Code 00 Slave 1 Multi...

Page 9: ...0VAC BUS IM BUS DS PC6A AC 1 4 5 6 9 8 0 7 2 3 Code 00 Master Code 00 Slave 1 Code 00 Slave 2 Code 00 Slave 3 With DBC4A1 Wiring Mode 4 Max IMPORTANT Subject to cable type Please see cable distance ch...

Page 10: ...DX or CDV47MG When an image at a door station is displayed move to the desired position by touching on the screen to view the image in zoom mode If greater detail about visitors is required move to th...

Page 11: ...mode The default setting is as the cancel button and asconfirm button please refer to function 8 setting below for detailed information Sliding a finger to touch the digital keypad may cause erroneou...

Page 12: ...s 0 1 0 102 12 SPK Volume Adjust Valid keys 0 9 4 11 13 Device Address Valid keys 0 3 0 12 14 Night Light Level Valid keys 0 5 4 13 Password for relay1 Temporary Code Single Use only Temporary Code Si...

Page 13: ...With power on and the reset is activated the key illumination will blink and the touching will not operate once complete the key illumination will stop flashing and a long beep will be emitted When t...

Page 14: ...tone is set to 1 pressing the digital keypad will flash one time ex 1 Enter the req Enter the code Enter the code req req range 0 on 1 off Beep Beep Beep Beep ex 1 range 0 normal 1 reverse When set t...

Page 15: ...a call is in progress When in talking mode enter the Master code the LED turns white to activate the volume adjusting function MIC adjustment 1 up 4 down Speaker adjustment 3 up 6 down The colour of k...

Page 16: ...2 device address 2 3 device address 3 Night Light Level 0 5 The higher the number the brighterthe night lights The colour of key indicator The colour of key indicator The colour of key indicator The...

Page 17: ...t before will be cleared at the same time The user code can not be set the same as the master code and temporary code The colour of key indicator The colour of key indicator The colour of key indicato...

Page 18: ...1 range 0 a partment 1 villa Enter the code req ex 1 range Valid keys 0 9 0 apartment multiway 1 villa House When the work mode is villa thecall address 00 or 16 Scene 0 standby blue calling blue blin...

Page 19: ...assword is entered the buzzer will sound of beep beep beep When the registered user code has been entered using the keypad 1 12 digits the LED background indicator lights up the buzzer sounds and the...

Page 20: ...1 mm2 80 80 40 When Monitor quantity 20 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1 5 mm2 70 50 30 9 Cable Requirements The maximum distance of the wiring is limited within the...

Page 21: ...the right adaptor which is supplied by the manufacture or approved by the manufacture Pay attention to the high voltage inside the products please refer service only to a trained and qualified profess...

Page 22: ...Note...

Page 23: ...Note...

Page 24: ...The design and specifications can be modified without notice to the user Right to interpret and copyright of this manual are reserved CDV ENG 611 F KP V1 190307...

Reviews: