background image

G0301FR0145V01   Ed : 0799 

 

Français / English /Italiano 

 

RACCORDEMENT/WIRING: 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

N°BORNE 

SIGNAL 

SORTIE 

1 contact 

repos 

relais 

2 commun 

contact travail relais 

4 alimentation 

12V 

 

5 alimentation 

12V 

 

entrée bouton poussoir 

entrée bouton poussoir 

8 contact 

surveillance 

 

9 contact 

surveillance 

 

10 contact 

repos 

relais 

11 commun 

12 contact 

travail 

TERMINAL   

DESCRIPTION 

OUTPUT  

1 N/C 

contact 

 

2 Common 

 

3 N/O 

contact 

 

Power supply 12V  

 

Power supply 12V  

 

Request to exit input  

Request to exit input  

Tamper switch output  

 

Tamper switch output  

 

10 N/C 

contact 

 

11 Common 

 

12 N/O 

contact 

 

TERMINAL N  

SIGNAL 

OUTPUT  

Contatto N/C  

2 Comune 

 

Contatto N/O   

4 Alimentazione12V 

 

 

5 Alimentazione12V 

 

 

6 Pulsante 

uscita 

 

7 Pulsante 

uscita 

 

Tamper switch output  

 

Tamper switch output  

 

10 

Contatto N/C  

11 Comune 

 

 

12 

Contatto N/O  

 

 

3

 

 

 

5

 

 

 

8

 

 

 

9

 

 

 

12

 

 

 

11

 

 

 

10

 

 

 

1

 

 

 

2

 

 

 

4

 

 

 

RL2

 

 

 

RL1

 

 

 

Alimentazione

 

 

 

12 V

 

 

 

DC or AC

 

 

 

115V AC

 

 

 

STRIKE 1

 

 

 

STRIKE 2

 

 

 

Allarme

 

 

 

T

 

 

 

C

 

 

 

R

 

 

 

R

 

 

 

C

 

 

 

T

 

 

 

6

 

 

 

7

 

 

 

PB

 

 

 

jumper

 

 

 

 

 

3

 

 

 

5

 

 

 

8

 

 

 

9

 

 

 

12

 

 

 

11

 

 

 

10

 

 

 

1

 

 

 

2

 

 

 

4

 

 

 

RL2

 

 

 

RL1

 

 

 

ALIMENTATION

 

 

 

12 V

 

 

 

DC ou AC

 

 

 

230V AC

 

 

 

GACHE 1

 

 

 

GACHE 2

 

 

 

ALARME

 

 

 

T

 

 

 

C

 

 

 

R

 

 

 

R

 

 

 

C

 

 

 

T

 

 

 

6

 

 

 

7

 

 

 

BP

 

 

 

picots

 

 

 

  

ALIMENTATION   

12 V   

DC ou AC   

230V AC   

ALARME   

BP   

Summary of Contents for C2R

Page 1: ...is 2 mode impulsionnel 1 seconde CODE 0 00000 code ma tre d entr e en programmation PROGRAMMATION DU CODE MAITRE Taper deux fois de suite 00000 Le voyant jaune s allume fixe Taper 0 puis les 5 termes...

Page 2: ...ommander simultan ment les 2 relais TEMPORISATIONS DE SECURITE Temporisation interchiffre frappe clavier 10 secondes Temporisation sortie programmation 60 secondes le voyant jaune clignote puis s tein...

Page 3: ...ing mode the yellow LED lights off SETTING THE USER CODES Enter the master code twice the yellow LED lights on Enter the user number from 1 to 8 then the 5 digit code the yellow LED lights off during...

Page 4: ...10 seconds maximum Programming mode exit delay 60 seconds maximum Lockout delay 30 seconds GENERAL RESET Cut the power supply of the keypad Short circuit with the jumper Put the power supply back for...

Page 5: ...o Premere per uscire dalla programmazione il LED giallo si spegne IMPOSTAZIONE DEI CODICI UTENTE Inserire il codice master due volte Il led giallo si accende Inserire il numero utente da 1 a 8 e digit...

Page 6: ...ELE 2 Rosso LED Un codice utente pu essere programmato nei due gruppi per ottenere l apertura simultanea dei due rel Ritardo di siqurezza Ritardo inserimento cifre 10 secondi massimo Uscita dalla prog...

Page 7: ...Request to exit input 1 7 Request to exit input 1 8 Tamper switch output 9 Tamper switch output 10 N C contact 2 11 Common 2 12 N O contact 2 TERMINAL N SIGNAL OUTPUT 1 Contatto N C 1 2 Comune 1 3 Co...

Page 8: ...t e directement sur les bornes de la g che connect e La varistance supprimera tous les parasites ou champs lectromagn tiques caus s par la bobine de la g che effet de self PROTECTION Questo prodotto c...