JUMPER SETTING AND WIRING DIAGRAM:

26-bit Wiegand ouput (Default)

+5V (Default)

+12V

30-bit Wiegand ouput

44-bit Wiegand ouput

1 = ON: External Buzzer Activation
2 = ON: External LED Activation

1 = OFF: Internal Buzzer Activation  (Default)
2 = OFF: Internal LED Activation  (Default)

BUZZER AND LED DIPSWITCH SETTINGS

ON

1 2

ON

1 2

DIPSWITCH setting will take effect at power up only

DGLI F WLC

DGLP FN WLC

ON

1 2

ON

1 2

PULL UPS JUMPER SETTING

WIEGAND OUTPUT JUMPER SETTING

CT-V900-A

2-Door  Controller

DO

GND

D1

12V
OUT1

OUT2
OUT5

GREEN

BLACK

WHITE

RED
YELLOW

(green LED)

ORANGE

(red LED)

BROWN

(buzzer)

Blue

(Clock)

Not applicable with 
Centaur System

Reader wiring is shown with a 2-door 
controller  CT-V900-A and default jumper 
setting of the reader (see above). It may differ 
from other controllers. Please consult the 
manufacturer for details.

DGLP FN 

WLC

DGLI F 

WLC

CAT5 CABLE

(unshield 4 twisted paire cable)

ON

1 2

H

D0

D1

B

-

R

V

+

26-bit Wiegand ouput (Default)

+5V (Default)

+12V

30-bit Wiegand ouput

44-bit Wiegand ouput

1 = ON: External Buzzer Activation

2 = ON: External LED Activation

1 = OFF: Internal Buzzer Activation  (Default)

2 = OFF: Internal LED Activation  (Default)

ON

1 2

ON

1 2

DIPSWITCH setting will take effect at power up only

ON

1 2

H

D0

D1

B

-

R

V

+

DGLP WLC

or

DGLI WLC

BUZZER AND LED DIPSWITCH SETTINGS

PULL UPS JUMPER SETTING

WIEGAND OUTPUT JUMPER SETTING

CT-V900-A

2-Door  Controller

CAT5 CABLE

(unshield 4 twisted paire cable)

DO
GND

D1
12V

OUT1
OUT2

OUT5

DO
-

D1

+

V

(green LED)

R

(red LED)

B

(buzzer)

H

(Clock)

Not applicable with 

Centaur System

Reader wiring is shown with a 

2-door controller  CT-V900-A 

and default jumper setting of 

the reader (see above). It 

may differ from other 

controllers. Please consult 

the manufacturer for details.

or

DGLP WLC

DGLI WLC

Summary of Contents for DGLP WLC

Page 1: ...INSTALLATION MANUAL Indoor Outdoor Wiegand Proximity Readers DGLP WLC DGLP FN WLC DGLI WLC DGLI F WLC...

Page 2: ...5 42 mm 1 7 23 mm 9 PRODUCT OVERVIEW The DGLP WLC and DGLI WLC are two Wiegand Proximity readers availa ble as standard size and narrow style DGLP FN WLC et DGLI F WLC Both readers are sealed with ep...

Page 3: ...readers ARD12 BS60 Optional Single gang box mounting plate for the DGLP FN WLC reader Ref MPLATE Important To protect the device from back emf do not forget to mount the varistor on the lock in parall...

Page 4: ...nnect the cable to the terminal block then fasten the reader with the DIAX screws using the DIAX spanner Make sure that the varistor is connected on the lock refer to page 2 Recommendations DGLP WLC I...

Page 5: ...the reader with the DIAX screws using the DIAX spanner Make sure that the varistor is connected on the lock refer to page 2 Recommendations DGLP FN WLC Insert the plastic anchors in the mounting holes...

Page 6: ...PSWITCH setting will take effect at power up only DGLI F WLC DGLP FN WLC ON 1 2 ON 1 2 PULL UPS JUMPER SETTING WIEGAND OUTPUT JUMPER SETTING CT V900 A 2 Door Controller DO GND D1 12V OUT1 OUT2 OUT5 GR...

Page 7: ...e effect at power up only ON 1 2 H D0 D1 B R V DGLP WLC or DGLI WLC BUZZER AND LED DIPSWITCH SETTINGS PULL UPS JUMPER SETTING WIEGAND OUTPUT JUMPER SETTING CT V900 A 2 Door Controller CAT5 CABLE unshi...

Page 8: ...1 882 18 41 Fax 41 0 21 882 18 42 CDV CHINA CHINA Tel 86 0 10 87664065 Fax 86 0 10 87664165 CDV IB RICA SPAIN Tel 34 936 916 551 Fax 34 935 801 278 CDV ITALIA ITALIA Tel 39 0331 97 38 08 Fax 39 0331 9...

Reviews: