Installation Manual
w w w . c d v g r o u p . c o m
Wiegand Proximity Readers
JUMPER SETTING AND WIRING DIAGRAM:
26-bit Wiegand ouput (Default)
+5V (Default)
+12V
30-bit Wiegand ouput
44-bit Wiegand ouput
1 = ON: External Buzzer Activation
2 = ON: External LED Activation
1 = OFF: Internal Buzzer Activation (Default)
2 = OFF: Internal LED Activation (Default)
BUZZER AND LED DIPSWITCH SETTINGS
ON
1 2
ON
1 2
DIPSWITCH setting will take effect at power up only
DGLI F WLC
DGLP FN WLC
ON
1 2
ON
1 2
PULL UPS JUMPER SETTING
WIEGAND OUTPUT JUMPER SETTING
CT-V900-A
2-Door Controller
DO
GND
D1
12V
OUT1
OUT2
OUT5
GREEN
BLACK
WHITE
RED
YELLOW
(green LED)
ORANGE
(red LED)
BROWN
(buzzer)
Blue
(Clock)
Not applicable with
Centaur System
Reader wiring is shown with a 2-door
controller CT-V900-A and default jumper
setting of the reader (see above). It may differ
from other controllers. Please consult the
manufacturer for details.
DGLP FN
WLC
DGLI F
WLC
CAT5 CABLE
(unshield 4 twisted paire cable)
ON
1 2
H
D0
D1
B
-
R
V
+
26-bit Wiegand ouput (Default)
+5V (Default)
+12V
30-bit Wiegand ouput
44-bit Wiegand ouput
1 = ON: External Buzzer Activation
2 = ON: External LED Activation
1 = OFF: Internal Buzzer Activation (Default)
2 = OFF: Internal LED Activation (Default)
ON
1 2
ON
1 2
DIPSWITCH setting will take effect at power up only
ON
1 2
H
D0
D1
B
-
R
V
+
DGLP WLC
or
DGLI WLC
BUZZER AND LED DIPSWITCH SETTINGS
PULL UPS JUMPER SETTING
WIEGAND OUTPUT JUMPER SETTING
CT-V900-A
2-Door Controller
CAT5 CABLE
(unshield 4 twisted paire cable)
DO
GND
D1
12V
OUT1
OUT2
OUT5
DO
-
D1
+
V
(green LED)
R
(red LED)
B
(buzzer)
H
(Clock)
Not applicable with
Centaur System
Reader wiring is shown with a
2-door controller CT-V900-A
and default jumper setting of
the reader (see above). It
may differ from other
controllers. Please consult
the manufacturer for details.
or
DGLP WLC
DGLI WLC