CDV Group DGLP WLC Installation Manual Download Page 4

w w w . c d v g r o u p . c o m

Installation Manual

w w w . c d v g r o u p . c o m

Wiegand Proximity Readers

• Indoor / outdoor application
• Selectable Wiegand output, 26, 30 or 44-bits    
• LED and built-in buzzer (internal or external mode)
• Potted electronics
• Input voltage: 12V DC
• Consumption: 100mA    

RECOMMENDATIONS:

CONTENTS:

Recommended cables

4 twisted pairs 0.6 MM.

Suggested power supplies

These power supplies are 
recommended with these Wiegand
readers:
- ARD12
- BS60

Optional

Single gang box mounting plate
for the DGLP FN WLC reader
(Ref: MPLATE).

Important 

To protect the device from back - emf 
do not forget to mount the varistor on 
the lock in parallel.

Environment

If the readers are mounted in a 
humid area or close to a sea shore, 
we recommend applying a varnish 
on the connections of the cable to 
avoid oxidation.

Varistor

Diax® 

security

tool

Diax®  

security

screw

Brass

anchor

Right 

cover

Left 

cover

Plastic

anchor

Wood 

screw

3 x 40 

mm

DGLI WLC &

DGLI F WLC

1

1

2

2

-

-

-

-

DGLP WLC &

DGLP F WLC

1

-

-

-

2

2

2

2

FEATURES:

Measure and mark the center lines to 
determine the reader position. Drill the fixing 
screw holes (Diametre: 4MM for the mounting 
plate and 6MM for the reader). Drill the wiring 
access area.

DGLI WLC
Insert the brass anchors in the mounting 
holes, connect the cable to the terminal block, 
then fasten the reader with the DIAX® screws 
using the DIAX® spanner. Make sure that the

 

varistor is connected on the lock (refer to page 
2 «Recommendations»).

DGLP WLC
Insert the plastic anchors in the mounting 
holes, connect the cable to the terminal block, 
Then fasten the reader with the wooden 
screws Leave an area to access the cable 
to make the wiring). Put the covers on top 
of the reader. Make sure that the varistor 
is connected on the lock (refer to page 2 
«Recommendations»).

MOUNTING INSTRUCTIONS:

1

2

3

Ref : DGLP WLC and DGLI WLC

Summary of Contents for DGLP WLC

Page 1: ...INSTALLATION MANUAL Indoor Outdoor Wiegand Proximity Readers DGLP WLC DGLP FN WLC DGLI WLC DGLI F WLC...

Page 2: ...5 42 mm 1 7 23 mm 9 PRODUCT OVERVIEW The DGLP WLC and DGLI WLC are two Wiegand Proximity readers availa ble as standard size and narrow style DGLP FN WLC et DGLI F WLC Both readers are sealed with ep...

Page 3: ...readers ARD12 BS60 Optional Single gang box mounting plate for the DGLP FN WLC reader Ref MPLATE Important To protect the device from back emf do not forget to mount the varistor on the lock in parall...

Page 4: ...nnect the cable to the terminal block then fasten the reader with the DIAX screws using the DIAX spanner Make sure that the varistor is connected on the lock refer to page 2 Recommendations DGLP WLC I...

Page 5: ...the reader with the DIAX screws using the DIAX spanner Make sure that the varistor is connected on the lock refer to page 2 Recommendations DGLP FN WLC Insert the plastic anchors in the mounting holes...