44
Fig. 40
D
B
PE
A
N
L
230 V
PE
N
L
1
(L
2
)
Fig. 41
Electrical feeder cable connection
To connect the supply cable:
- Remove the screws securing the cover “
A
” on the rear of the cooker (fig. 40).
- Feed the supply cable through the cable clamp “
D
”. The supply cable must be of a
suitable size for the current requirements of the appliance; see the section “Feeder
cable section” (fig. 40).
- Connect the wires to the terminal block “
B
” as shown in the diagram in figure 41;
or connect the phase wires to the terminal block “
B
” and the earth wire to the
terminal PE as shown in figure 40.
- Take up any slack in the cable and secure with the cable clamp “
D
”.
- Replace the cover “
A
”.
Before effecting any intervention on the electrical parts of the appliance, the
connection to the network must be interrupted.
Feeder cable section type H05RRF
230 V
3 x 2,5 mm
2
(**)
(**) – Connection with wall box connection.
Earth cable must be 2 cm longer than neutral and live cables.
Summary of Contents for RC9020