18
This cooktop can be built into a working surface 30 to 40 mm
thick and 600 mm deep.
In order to install the ceramic hob into the kitchen fixture, a
hole with the dimensions shown in figure 3 has to be made,
keeping in consideration the following:
– The cooktop shall not be installed directly above a
dishwasher, fridge, freezer, washing machine or clothes dryer,
as the humidity may damage the cooktop electronics.
– If the cooktop is installed above an oven, the oven shall
be provided with cooling fan. The two appliances should
be connected to the electrical supply with independent
connections.
– IMPORTANT WARNING! This cooktop requires
adequate supply of fresh, cool air to fully function.
The base of the cooktop must have direct unrestricted
ventilation to the room where the cooktop is installed.
Follow the requirements of figure 5.
– The ceramic hob must be kept no less than 60 mm away from
any side wall (see figure 4).
– The rear wall must be at least 50 mm from the ceramic hob
(see figure 3).
– There must be a distance of at least 650 mm between the
hob and any wall cupboard or extractor hood positioned
immediately above (see fig. 4).
– The coatings of the walls of the unit or appliances near
the cooktop must be heat resistant.
– Do not install the appliance near inflammable
materials (eg. curtains).
500 mm
650 mm
450 mm
Fig. 4
60 mm minimum between the side
of the cut-out and the side wall
7 mm
7 mm
min 30 mm
min 30 mm
70 mm
Fig. 5
Minimum clearances and
ventilation requirements
(cupboard or drawer space below)
Minimum clearances and
ventilation requirements
(oven installed below)
Oven with
cooling fan
Summary of Contents for HVN 32 Series