background image

8

down for a few seconds (can be as long as 10 seconds) to allow the 
flame failure device to detect the presence of the flame. 

Once lit, release the control knob and turn it to the desired position 
i.e. until the burner flame is at the required intensity.

Once you have finished cooking with the burner(s) in use, return the 
control knobs to the closed (off) position. 

Please note:

The ignition should not be operated (clicking constantly) for more 
than 15 seconds at a time. 

If a burner does not ignite, or turns off accidentally, turn the control 
knob to the closed (off) position. Wait for one minute before attempting 
to reignite the burner. The flame failure device will activate within 
approximately 60 seconds.

If the burner does not ignite, repeat the ignition process with the 
control knob at the minimum position. 

If a burner continues to not ignite, please follow the troubleshooting 
section on page 11. If the burner has been in use recently, allow it to 
cool sufficiently before handling it.

Summary of Contents for HVG970

Page 1: ...www cda eu HVG970 Five Burner Gas Hob Installation use and maintenance...

Page 2: ...tenance 11 Troubleshooting 12 What to do if you smell gas 15 Mains Electricity Connection 16 Technical Information 17 Gas Supply Requirements 18 Ventilation 18 Natural Gas to LPG Conversion 19 LPG to...

Page 3: ...h reduced physical sensorial or mental capacity or who lack experience or knowledge about it unless they have had supervision or instructions on how to use the appliance by someone who is responsible...

Page 4: ...OF THE PRODUCT IN ACCORDANCE WITH EU DIRECTIVE 2012 19 EU At the end of its working life the product must be taken to a special local authority waste collection centre or to a dealer providing applia...

Page 5: ...s correctly adjusted for the type of gas available before installation The use of a gas appliance produces heat and humidity in the room in which it is installed Ensure that the room is well ventilate...

Page 6: ...Medium burner 2 0kW 2 Large burner 3 0kW 3 Medium burner 2 0kW 4 Auxiliary burner 1 0kW 5 Ultra large burner 4 0kW Control knobs 6 Front left 7 Back left 8 Central 9 Back right 10 Front right Fig 1 6...

Page 7: ...closed off position Attempting to ignite the burner in a clockwise direction from the closed position may cause damage to the hob Igniting the gas burners This hob s burners are fitted with flame fail...

Page 8: ...hould not be operated clicking constantly for more than 15 seconds at a time If a burner does not ignite or turns off accidentally turn the control knobtotheclosed off position Waitforoneminutebeforea...

Page 9: ...st efficient use of the hob is shown below where the pan and burner are correctly chosen Use pan lids where possible to minimize the energy usage of your appliance Ensure that the pans do not overlap...

Page 10: ...leaners are available The cast iron parts of hobs pan stands and burner caps on this model are not suitable for cleaning in dishwashers They should be washed by hand and dried thoroughly afterwards wi...

Page 11: ...rs are clean and free from grease and debris on both sides 5 Check that the burners and the burner caps are clean and not soiled Dirt food debris and other particles can clog the burners causing issue...

Page 12: ...storage vessel s Metered installations shut off the ECV at the meter installation outside the building Cylinder fed installations shut all cylinder valves 2 Extinguish all naked flames Do not smoke i...

Page 13: ...hire boat owners etc may have their own responsibilities in the event of a gas leak so always contact the relevant site owner authority Northern Ireland Natural Gas 0800 002 001 Northern Ireland Gas E...

Page 14: ...Isles are shown below Calor 08457 444 999 BP 0845 607 6118 Flogas 0845 7200 100 Shell 0870 7539 999 Please note The CDA Group Ltd makes no warranty about the content of this section and will not be h...

Page 15: ...h the I E T and local regulations This appliance is NOT suitable for connection to a 13A plug or 13A supply Please note The mains cable must only be replaced by a qualified electrician or service engi...

Page 16: ...ecting to the fuse spur proceed as follows The wire which is coloured green and yellow must be connected to the terminal marked E Earth or coloured green The wire which is coloured blue must be connec...

Page 17: ...their name address and registration number Information supplied will be validated before help is provided In the event that this appliance is not installed in accordance with the above requirements th...

Page 18: ...pliances in the same room consult the relevant British Standard BS5440 or GAS SAFE Document Natural Gas to LPG Conversion This hob can be converted from natural gas to propane operation at a nominal i...

Page 19: ...o the minimum position make sure the flame does not extinguish 5 Replace the knobs LPG to Natural Gas Conversion This hob can be converted from propane operation at a nominal inlet pressure of 37mbar...

Page 20: ...than 750mm then that height is the minimum required Wall furniture requirements The minimum height of any cabinet immediately above the hob is 900mm The minimum height of any adjacent units including...

Page 21: ...s Width 860mm Depth 484mm A gap of 75mm is required below the hob for ventilation purposes Fig 9 This must be measured from the gas hob elbow 1 Make the required hole in the worktop Note that before d...

Page 22: ...22 860mm 490mm 61 5mm 300mm 300mm 420mm 750mm Fig 6 Fig 7 m m 0 1 5 A B 500x20 mm 500x10 mm A B B m m 5 7 n i m B m m 0 1 5 C C 500x10 mm min 30 mm m m 5 7 n i m Fig 9 860 0 9 4 0 1 5 2 500 320 Fig 8...

Page 23: ...ance The gas hob is designed for domestic use only please do not use for commercial purposes The gas hob is designed for use with gas LPG and Natural gas The combustion products contain carbon monoxid...

Page 24: ...9HY T 01949 862 012 F 01949 862 003 E customer care cda eu For service or queries relating to your product please contact The Customer Care Department on 01949 862 012 or email customer care cda eu Fo...