Natural Gas to LPG Conversion
This hob can be converted from natural gas to propane operation at a
nominal inlet pressure of 37mbar, or butane operation at a nominal
inlet pressure of 28/30mbar. This conversion must only be carried out
by a competent person (i.e. a Gas Safe registered fitter).
Instructions to fit replacement
injectors:
1. Disconnect the appliance from the
gas and electrical supplies.
2. Remove burner components and pan
supports.
3. Remove the injectors and replace
with the corresponding injector as
shown in the table below.
Setting up minimum flow rates:
1. Remove the control knobs.
2. Turn on the LP gas supply, light the
burners and turn the controls to the
minimum position, as indicated by
the small flame.
3. Insert a 2.5mm screwdriver into the
hole at the top of the tap and turn the
adjustment screw fully clockwise as
shown in Fig.4.
Required:
•
7mm AF nut spinner
•
Replacement injectors
•
LPG identity plate
Fig.4