16
J
Auxiliary, Semi-rapid
and Rapid
burner
REPLACEMENT OF THE INJECTORS
If the injectors are not supplied they can be
obtained from the “Service Centre”.
Select the injectors to be replaced according
to the “TABLE FOR THE CHOICE OF THE INJEC-
TORS”.
The nozzle diameters, expressed in hun-
dredths of a millimeter, are marked on the
body of each injector.
REPLACEMENT OF THE INJECTORS OF
THE COOKTOP BURNERS
To replace the injectors proceed as follows:
•
Remove pan supports and burners from
the cooktop.
•
Using a wrench, substitute the injectors
“
J
” (figs. 8, 9) with those most suitable for
the kind of gas for which it is to be used.
The burners are conceived in such a way so
as not to require the regulation of the pri-
mary air.
J
Triple-ring burner
Fig. 8
Fig. 9
SETTING THE MINIMUM OF THE
COOKTOP BURNERS
In the minimum position the flame must have
a length of about 4 mm and must remain lit
even with a quick turn from the maximum po-
sition to that of minimum.
The flame adjustment is done in the following
way:
•
Turn on the burner.
•
Turn the tap to the 'MINIMUM' position.
•
Take off the knob.
•
With a small flat screwdriver turn the
screw “
A
” to the correct regulation (fig.
10).
Normally for LPG tighten up the regulation
screw.
Fig. 10
A
Summary of Contents for HG9321SS
Page 1: ...1 www cda eu GB HG9321SS Built in Cooking Hob Installation Use and Maintenance...
Page 6: ...6...
Page 7: ...7 ADVICE ADVICE for the for the INSTALLER INSTALLER...
Page 18: ...18...
Page 19: ...19 ADVICE ADVICE for the for the USERS USERS...
Page 26: ...26 Fig 11 Fig 12 Fig 13 Fig 14 S F C T A B S T Fig 10...