CDA he6050ss Manual For Installation, Use And Maintenance Download Page 12

12

Notes:

•   

Do not position this appliance above a refrigeration unit. The heat 
generated may cause the unit to fail.

•   

This appliance is designed to be installed into cabinet units capable of 
withstanding temperatures of 65°C above ambient or greater (typically 
80-90°C).

•   

If the hob is to be installed above a working drawer, then a partition 
should be fitted to protect the contents and user from  the heat 
generated during use. This should be fitted 100mm below the hob. 

•  

Never place perishable foods in the cupboard below the appliance.

How To Install The Hob

How to install the hob:

Overall dimensions of the hob:  

Width: 580mm  

Depth: 500mm

Worktop cut-out dimensions:  

Width: 557mm  

Depth: 477mm

1.    Make the required hole in the worktop. Note that before doing this, 

check the instructions supplied with any cooker hood to ensure that 
you will have the required clearance. The cut-out (Fig 3) shows a 
61.5mm gap from the wall to the cut-out edge. The distance for the 
hob, when fitted, to the back wall is 50mm.

2.   Position the hob seal, as shown in the diagram below (Fig 5), ensuring 

that the ends meet without overlapping. Do not use silicone type 
sealant.

3.  Secure the hob to the worktop using the fixing brackets and screws 

supplied, as shown in the following diagram (Fig 6).  

 

 

Remove any excess sealant after tightening the brackets.

Summary of Contents for he6050ss

Page 1: ...Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E customer care cda eu W www cda eu he6050ss electric hob Manual for Installation Use and Main...

Page 2: ...2 Contents 3 Important 5 Important Notes 6 Using Your Hob 8 Efficient Use Of Your Hob 9 Care And Maintenance 11 Fitting The Hob 12 How To Install The Hob 14 Mains Electricity Connection...

Page 3: ...ildren with reduced physical sensorial or mental capacity or who lack experience or knowledge about it unless they have had supervision or instructions on how to use the appliance by someone who is re...

Page 4: ...UCT IN ACCORDANCE WITH EC DIRECTIVE 2002 96 EC At the end of its working life the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recyclin...

Page 5: ...t switch on the hotplates without cookware in place Do not lean over the hob when it is in use Follow the cleaning instructions carefully Ensure the base of the saucepan is clean and dry before placin...

Page 6: ...tings 5 6 7 8 9 Heat setting Description 1 Very gentle 2 Gentle 3 Slow 4 Medium 5 High 6 Very high Fig 1 1 2 3 4 Electric hotplates 1 180mm FL 1 5kW 2 145mm BL 1 0kW 3 180mm BR 2 0kW Rapid 4 145mm FR...

Page 7: ...en the hotplate is in use When you have finished cooking check to ensure that the hotplates are off and the indicator is not lit Before using your hob for the first time switch the hotplates on for a...

Page 8: ...ere the pan and hotplate are correctly chosen Use pan lids where possible to minimize the energy usage of your appliance Turn off each hotplate a few minutes before the end of cooking time The residua...

Page 9: ...e available IMPORTANT Steam cleaners must not be used when cleaning these appliances HOTPLATE CARE The finish of the cast iron hotplates is designed to be durable in use The following tips should be o...

Page 10: ...10 IF YOUR HOB IS NOT WORKING 1 Check that the mains supply has not been switched off 2 Check that the fuse or circuit breaker has not blown tripped...

Page 11: ...hown in Fig 3 If fitting a cooker hood above the hob If a cooker hood is to be installed above the hob the height of the hood above the hob must be at least 600mm 650mm is recommended Fig 4 If the ins...

Page 12: ...How to install the hob Overall dimensions of the hob Width 580mm Depth 500mm Worktop cut out dimensions Width 557mm Depth 477mm 1 Make the required hole in the worktop Note that before doing this chec...

Page 13: ...13 Fig 3 Fig 4 Fig 5 Fig 6 185mm 185mm 61 5mm 560cm 165mm 165mm 557mm 477mm 600mm 3cm 4cm...

Page 14: ...a contact separation of at least 3mm in all poles The switch must be positioned no further than 2m from the appliance Please note The mains cable must only be replaced by a qualified electrician or s...

Page 15: ...m Rapid 2 0 145mm Rapid 1 5 When installing this product we recommend you seek the help of another individual TECHNICAL DATA The table opposite shows the rated output of each hotplate Mains electrical...

Page 16: ...tact our Customer Care Department for Service on the details below Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W...

Reviews: