IMPORTANT: Ensure that any false ceiling will be capable of
supporting the weight of the product, which is approximately
18.7 kg (without the motor group). Your motor group should be
mounted onto a solid ceiling or wall.
Below (Fig. 2) is a diagram showing the overall extractor dimensions.
This is to aid you in preparation for installing the extractor.
Recommended niche/cut-out dimensions (due to hanging hooks)
= 900 x 500 mm
Please note:
If the nature of the install is such that you will not be able
to install the motor group and subsequent ducting once the extractor
body has been installed, then you will need to fit the motor group and
ducting now (i.e. before mounting the extractor body into the cut-out).
Remember: Always bear servicing in mind. Always ensure that the