Mounting your Extractor

When the extractor is to be installed above hob, the minimum 
distance between the hob and extractor must exceed 650mm.

If the instructions provided with your gas hob state that the 
required distance between the hob and extractor must be 
greater than 650mm, then that is the distance that should be 
observed; this is a legal requirement and may lead to your hob 
being disconnected from the gas supply and the installation 
being reported to RIDDOR (The height should be measured 
from the top of the burners).

IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED 
WITH THE GAS HOB, THE MINIMUM DISTANCE 
BETWEEN THE HOB AND EXTRACTOR MUST BE AT 
LEAST 760mm.

The width of any hob must not be greater than the width of 
the extractor installed above it. Fig. 5

Ducting and Ventilation

For best performance and lowest noise output, we 
recommend the use of 125mm or 150mm ducting. You can 
also use 100mm ducting but this will reduce performance.

Fig. 5

7

650mm recommended

Summary of Contents for EVPC9

Page 1: ...or Manual for Installation Use and Maintenance Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionat...

Page 2: ...y EMC IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002 96 EC At the end of its working life the product must be taken to a special local authority waste c...

Page 3: ...s selected speed To activate the intensive function touch key D at speed three The display will blink whilst the intensive function is on The timer The extractor is equipped with a timer that allows t...

Page 4: ...s has been replaced the electronic memory must be reset by touching key A for approximately five seconds until the letter A stops flashing To remove the grease filters follow the steps below 1 Pull op...

Page 5: ...ver Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights The light is designed for use during cooking and not for general room illumination Extended use of the lig...

Page 6: ...st be connected to the terminal marked N Neutral or coloured black The wire which is coloured brown must be connected to the terminal marked L Live or coloured red NOTE USE A 3A FUSE Assembly and elec...

Page 7: ...s electrical voltage 230 240Vac 50Hz Total rated power consumption 310W Troubleshooting If your extractor is not working 1 Check that the mains supply has not been switched off 2 Check that the fuse i...

Page 8: ...being disconnected from the gas supply and the installation being reported to RIDDOR The height should be measured from the top of the burners IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS...

Page 9: ...the template D on the wall and mark the positions of the drill holes on the wall Note that the bottom edge of the template should be the height required above the hob Fig 6 2A 2 Drill holes suitable...

Page 10: ...pipe as shown if Fig 10 If using the extractor as a re circulation device assemble the vent diverter and connect the ducting and vent adaptor as shown in Fig 11 7 Fit the chimney sections Y and secur...

Page 11: ...10...

Page 12: ...roup Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionate about style To contact our Customer Care Department or for Service please c...

Reviews: