Important

The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. 
Please note that the manufacturer reserves the right to invalidate the guarantee supplied with this product following 
incorrect installation or misuse of the appliance or use in a commercial environment. 

This appliance is not designed to be used by people (including children) with reduced physical, sensorial or mental 
capacity, or who lack experience or knowledge about it, unless they have had supervision or instructions on how to use 
the appliance by someone who is responsible for their safety.

Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified 
personnel.

Appliance information:
Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a 
fault with your appliance and to register your appliance for guarantee purposes.

  Appliance Model

  Serial Number

CE Declarations of Conformity:
This appliance has been manufactured to the strictest standards and complies with all applicable legislation, including Gas 
safety, Electrical safety (LVD) and Electromagnetic interference compatibility (EMC).
 
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC 
DIRECTIVE 2002/96/EC.

At the end of its working life, the product must be taken to a special local authority waste collection centre or to a 
dealer providing appliance recycling services.  Disposing of a household appliance separately avoids possible negative 
consequences for the environment and health. It also enables the constituent materials to be recovered, saving both 
energy and resources. As a reminder of the need to dispose of household appliances separately, the product is marked 
with a crossed-out wheeled dustbin.

Please note:

   Under no circumstances should the extractor be connected to any gas ventilation system, flue system or hot air    

 

ducting system.

   Do not vent the extractor into an attic or loft space.

   Only house the extractor in rooms with adequate ventilation. Remember that the extractor is powerful and  

 

 

whatever air is extracted needs to be replaced.

   Do not tile the extractor in. It should be removable for service or maintenance.

   Do not use silicone sealant to secure the hood to the wall.

   You must be able to isolate the extractor from the mains electrical supply after installation.

   Steam cleaners must not be used when cleaning this appliance.

   The performance of your extractor will vary depending on a number of factors. These include: type of extraction,  

 

length of ducting, room volume, ventilation available and cleanliness of the filters.

1

Summary of Contents for EVPC9

Page 1: ...or Manual for Installation Use and Maintenance Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionat...

Page 2: ...y EMC IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002 96 EC At the end of its working life the product must be taken to a special local authority waste c...

Page 3: ...s selected speed To activate the intensive function touch key D at speed three The display will blink whilst the intensive function is on The timer The extractor is equipped with a timer that allows t...

Page 4: ...s has been replaced the electronic memory must be reset by touching key A for approximately five seconds until the letter A stops flashing To remove the grease filters follow the steps below 1 Pull op...

Page 5: ...ver Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights The light is designed for use during cooking and not for general room illumination Extended use of the lig...

Page 6: ...st be connected to the terminal marked N Neutral or coloured black The wire which is coloured brown must be connected to the terminal marked L Live or coloured red NOTE USE A 3A FUSE Assembly and elec...

Page 7: ...s electrical voltage 230 240Vac 50Hz Total rated power consumption 310W Troubleshooting If your extractor is not working 1 Check that the mains supply has not been switched off 2 Check that the fuse i...

Page 8: ...being disconnected from the gas supply and the installation being reported to RIDDOR The height should be measured from the top of the burners IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS...

Page 9: ...the template D on the wall and mark the positions of the drill holes on the wall Note that the bottom edge of the template should be the height required above the hob Fig 6 2A 2 Drill holes suitable...

Page 10: ...pipe as shown if Fig 10 If using the extractor as a re circulation device assemble the vent diverter and connect the ducting and vent adaptor as shown in Fig 11 7 Fit the chimney sections Y and secur...

Page 11: ...10...

Page 12: ...roup Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionate about style To contact our Customer Care Department or for Service please c...

Reviews: