Mains electrical connection 

Warning! This appliance must be earthed.

This appliance must be connected by

a competent person, using fixed wiring

via a double pole switched fused spur

outlet, protected by a 3A fuse.

GREEN AND YELLOW = EARTH 

BLUE = NEUTRAL 

BROWN = LIVE

As the colours of the wires in the mains lead for the appliance may

not correspond with the coloured markings identifying the 

terminals in your spur box, proceed as follows:

We recommend that the appliance 

is connected by a qualified

electrician, who is a member of the 

N.I.C.E.I.C. and who will comply

with the I.E.T. and local regulations. 

The wires in the mains lead are

coloured in accordance with the 

following code:

1.   The wire which is coloured green and yellow must be 

connected to the terminal marked E (Earth) or coloured green

2.  The wire which is coloured blue must be connected to the   

 terminal marked N (Neutral) or coloured black

3.   The wire which is coloured brown must be connected to the 

terminal marked L (Live) or coloured red

FUSE

ON

USE A 3 AMP FUSE 

DOUBLE POLE SWITCHED FUSED 

SPUR OUTLET

Summary of Contents for EDD62

Page 1: ...EDD62 EDD92 Downdraft extractor Installation use and maintenance...

Page 2: ...ortant information 5 Using your extractor 7 Changing the charcoal filter 8 Mounting your extractor 8 Ducting and ventilation 9 Troubleshooting 10 Installation 12 Guarantee 13 Mains electrical connecti...

Page 3: ...hey have had supervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or mainte...

Page 4: ...der no circumstances should the extractor be connected to any gas ventilation system flue system or hot air ducting system Do not vent the extractor into an attic or loft space Only house the extracto...

Page 5: ...r off Once the extraction panel descends to halfway the lights will switch off automatically Touch the low key to start the fan at the lowest setting Touch again to turn off the fan Touching either th...

Page 6: ...d remove and clean the grease filter with hot soapy water You can also wash the grease filter in a dishwasher ensuring that you place it in an upright position to prevent damage from other items in th...

Page 7: ...on top of the motor housing box by turning the black screw counter clockwise as shown in fig 2 and remove the panel as shown in fig 3 Hold the tab of the filter towards you and lower the filter down i...

Page 8: ...ed to RIDDOR IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 30mm The width of any hob must not be greater than the wid...

Page 9: ...fuse replace if blown Wires have disconnected Ensure the power supply is securely connected Output of appliance is low Setting is too low for amount of fumes present Try a higher speed setting Inadeq...

Page 10: ...to accommodate the extractor allowing for the specified clearance between the final installed positions of the extractor and the hob 3 Make a rectangular cut out in the worktop to accommodate the extr...

Page 11: ...n the bracket to the cabinet interior Fig 8 The minimum distance between the bottom of the bracket and the bottom of the cabinet is 20mm and the maximum is 60mm Note Ensure that the extractor unit is...

Page 12: ...ified person Installation has been carried out in accordance with instructions and current legislations Proof of purchase can be produced The appliance has been used for domestic purposes only The app...

Page 13: ...ed as follows We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C and who will comply with the I E T and local regulations The wires in the mains...

Page 14: ...nergy Consumption AECHood kWh Time increase factor f FDEHood EEIHood Point QBEP m 3 h Point PBEP Pa Q w o fl r i a m u m i x a M MAX m 3 h Measured electric power at Best WBEP W Nominal lighting power...

Page 15: ...Instruction Manual 15 Notes...

Page 16: ...The CDA Group Harby Road Langar Nottinghamshire NG13 9HY Sales Department Phone 01949 862010 Email sales cda eu CDA Customer Care Phone 01949 862012 Email customer care cda eu 2020 CDA Group Ltd...

Reviews: