CDA edd61 Installation & Use Manual Download Page 12

12

Installation

Note

•   

We recommend that you seek the help of another individual when    
installing this product.

•   

The fixings supplied are suitable for most installations. It is the  

 

responsibility of the installer to ensure that the fixings are suitable 
for the cabinets in the property.

Installation

1)   Prior to installation, check that all parts are present and free from 

transit damage.  In event of damage being discovered contact your 
supplier and do not proceed with installation.

116

75

75

560/860

880

12

300

8

720

346

96

480/780

200

440

Ø150

Fig. 3

Summary of Contents for edd61

Page 1: ...r Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E customer care cda eu W www cda eu www cda eu edd61 edd91 Extractors Installation Use and Maintenance ...

Page 2: ...upervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel Appliance information Please enter the details on the appliance rating plate below for reference to assist CDA Customer Care in the event of a fault with your appliance ...

Page 3: ... dispose of household appliances separately the product is marked with a crossed out wheeled dustbin Please note Under no circumstances should the extractor be connected to any gas ventilation system flue system or hot air ducting system Do not vent the extractor into an attic or loft space Only house the extractor in rooms with adequate ventilation Remember that the extractor is powerful and what...

Page 4: ...e used when cleaning this appliance The performance of your extractor will vary depending on a number of factors These include type of extraction length of ducting room volume ventilation available and cleanliness of the filters ...

Page 5: ...hed off touch the On key once to raise the extraction panel to its full height The moving panel will raise to its operating position and the appliance will start to extract at its slowest speed once it reaches 180mm above its rest position To increase the speed wait until the extractor has reached its full height and is running at the first speed then touch the On key several times until the desir...

Page 6: ...eave the kitchen unattended Other features After approx 30 hours of operation the speed selelction display on the control panel will flash to signify that the grease filters are due for cleaning After they are cleaned and replaced page 8 press the Timer key once to reset the grease filter alarm timer After the appliance has been running for 4 hours since the last key touch it will automatically sh...

Page 7: ...r Any abrasive cleaner including Cif will scratch the surface and could erase the control panel markings You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth for example the CDA E Cloth Cleaning the grease filters The grease filters should be kept clean to minimise the risk of fire At least once a month you ...

Page 8: ...emoval procedure Please note Cleaning the grease filters in the dishwasher may lead to discolouration This is normal and does not constitute a fault with the appliance Changing the charcoal filters re circulating only To ensure best performance of your extractor you should replace the charcoal filters every four to six months depending on use To replace the charcoal filters Remove the grease filte...

Page 9: ... state that the required distance between the hob and extractor must be greater than specified above then that is the distance that should be observed this is a legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported to RIDDOR IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR...

Page 10: ...quate facility for air intake to the kitchen The charcoal filter if fitted is blocked Replace the charcoal filter The exit ducting is obstructed Remove any obstructions from the ducting The exit flaps on the motor housing are restricted Ensure the flaps rotate freely The hood stops in mid operation There ia a power outage Check the power supply The circuit breaker or fuse has tripped Check the cir...

Page 11: ...noise The length of ducting should not exceed 5 metres in total Limit the use of elbows in the ducting to a minimum Bear in mind that each elbow imposes a similar restriction to flow to a 1 metre length of straight ducting Avoid abrupt changes in direction for the ducting Ensure that the ducting used satisfies all local and national standards applicable to the installation ...

Page 12: ... the responsibility of the installer to ensure that the fixings are suitable for the cabinets in the property Installation 1 Prior to installation check that all parts are present and free from transit damage In event of damage being discovered contact your supplier and do not proceed with installation 116 75 75 560 860 880 12 300 8 720 346 96 480 780 200 440 Ø150 Fig 3 ...

Page 13: ...the final installed positions of the extractor and the hob 3 Before installation remove the transit pieces shown in fig 4 5 6 4 Make a rectangular cut out in the worktop to accommodate the extractor The dimensions of the cut out should be edd61 490 x 100mm edd91 790 x 100mm 5 If your extractor has been supplied with the motor unit already mounted on the main body this needs to be dismantled to ena...

Page 14: ...abinet using the special fixing brackets supplied Fig 9 i The brackets should first be attached to the extractor body in such a way that they leave a gap of approx 2mm between the brackets and the base of the cabinet ii The screws fixing the brackets to the cabinet base are then used to pull the downdraft extractor firmly into its final installed position Note Ensure that the downdraft extractor u...

Page 15: ... the cabinet no closer than 65mm to any gas operated hob and no closer than 65mm to the extraction outlet We recommend installing the box containing the electronics at least 10cm above floor level and at a suitable distance from all sources of heat e g oven sides hob base 12 Plug the 9 pin electrical connector from the electronic box into the downdraft body being careful to orientate it correctly ...

Page 16: ...e On key to start the moving panel rising After the panel has risen by approx 180mm touch the Off key to stop it from rising any further Touch the Timer key once After 2 seconds touch the Off key again The LED s on the control panel will flash to show that the downdraft extractor is carrying out its calibration procedure and the panel will raise lower When the calibration procedure is complete the...

Page 17: ...oved to BS 1362 type into the fuse cover 3 Replace fuse cover Important Do not use the appliance without the fuse cover in position How to connect an alternative plug If the fitted plug is not suitable for your socket outlet then it should be cut off and disposed of safely to avoid possible shock hazard A suitable alternative plug of at least 3 Amp rating to BS 1363 should be used Fig 17 B A Green...

Page 18: ...must be connected to the terminal which is marked with the letter N or coloured BLACK The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED If in doubt regarding the electrical connection of this appliance consult a qualified electrician Do not shorten the supply cable the appliance may require removing for servicing N B Ensure that th...

Page 19: ...19 E O E All instructions dimensions and illustrations are provided for guidance only CDA reserve the right to change specifications without prior notice ...

Page 20: ...2 F 01949 862 003 E customer care cda eu W www cda eu www cda eu Please contact our Customer Care Department for Service on the details below Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E customer care cda eu Copyright CDA 2014 ...

Reviews: