background image

6

GAS BURNERS

Gas flow to the burners is adjusted by turning the knob illustrated in fig. 3 which con-
trols the safety valves. 
Turning the knob so that the indicator line points to the symbols printed on the panel
achieves the following functions:

full circle

=

closed valve

symbol

=

maximum aperture or flow

symbol

=

minimum aperture or flow

The maximum aperture position permits rapid boiling of liquids, whereas the minimum
aperture position allows slower warming of food or maintaining boiling conditions of
liquids.
To reduce the gas flow to minimum, rotate the knob further anti-clockwise to point
the indicator towards the small flame symbol. 
Other intermediate operating adjustments can be achieved by positioning the indicator
between the maximum and minimum aperture positions, not between the maximum
aperture and closed positions.

LIGHTING OF BURNERS

To ignite the burners follow these instructions:

– Lightly press the knob (fig. 4) in an anti-clockwise direction up to the maximum aperture

(symbol 

); press the knob right down to prime the electric ignition until the burner lights.

In case of power cut manually light the burner.

– Adjust the burner according to the power required.

If the burner fails to ignite repeat the ignition with the knob on “minimum” position.

Figure 3

Figure 4

Use Of the Hob

Summary of Contents for CD 60

Page 1: ...Flush fitting hob front controls CD 60 CD 61 CD 62 Before operating this hob please read these instructions carefully Users Operating Instructions GB...

Page 2: ...nd therefore dangerous The manufacturer is not responsible for damage caused by improper incorrect or irresponsible use of the appliance TIPS FOR THE USER During and immediately after use some parts o...

Page 3: ...correct or irresponsible use of the appliance Before disposing of any unwanted appliances it is recommended that all potentially hazardous parts be made harmless The appliance should be installed and...

Page 4: ...4 Auxiliary burner A 1 00 kW CONTROL PANEL 5 Rapid burner control knob 1 6 Left medium speed burner control knob 2 7 Right medium speed burner control knob 3 8 Auxiliary burner control knob 4 This app...

Page 5: ...1 75 kW 3 Right medium speed burner SR 1 75 kW 4 Auxiliary burner A 1 00 kW CONTROL PANEL 5 Triple ring burner control knob 1 6 Left medium speed burner control knob 2 7 Right medium speed burner cont...

Page 6: ...m rotate the knob further anti clockwise to point the indicator towards the small flame symbol Other intermediate operating adjustments can be achieved by positioning the indicator between the maximum...

Page 7: ...ner fig 5 Attention During use the hob becomes very hot under the cooking zones Keep children away Figure 5 WRONG CORRECT Flat bottomed pans should be placed directly onto the pan support When using a...

Page 8: ...h are available on the market Dry preferably with chamois leather Note regular use will cause discolouring around the burners because of the high flame temperature BURNERS AND GRIDS These pieces can b...

Page 9: ...problems could arise Make sure that electrode S Fig 6 is kept clean so that the sparks always strike TRIPLE RING BURNER The triple ring burner must be correctly positioned see fig 7 the burner rib mu...

Page 10: ...turer s instructions Any repair or maintenance must be performed with the appliance switched off These appliances have been designed and manufactured to be fitted into heat resistant units These hobs...

Page 11: ...b and the top of a shelf Any wall to the side and above the hob must be at least 100 mm away Fig 9 The wall behind the hob must be at least 35 mm away Fig 9 When there is a wall unit or hood above the...

Page 12: ...screws to fasten it to units from 2 to 4 cm thick Turn the hob over and put tabs A into the mountings only tighten screws B a few turns Do not over tighten Make sure that the tabs are mounted correctl...

Page 13: ...it is possible for air to come from an adjacent room which is ventilated as required as long as it is not a bedroom or a dangerous area In this case the kitchen door must be left open to allow air mov...

Page 14: ...gas different than that indicated on the plate it is necessary to make the following changes gas connection replacement of the injectors regulating of the minimum flame GAS CONNECTION Cat II 2H3 The c...

Page 15: ...nection has been slackened with two spanners Fig 16 Never put it in the horizontal or vertical position IMPORTANT Never attempt to turn the elbow C without having first slackened off the relative lock...

Page 16: ...bs Using a wrench substitute the nozzle injectors J Fig 17 with those most suitable for the kind of gas for which it is to be used The burners are made in such a way so as not to require regulation of...

Page 17: ...ith adjusting screw on the body fig 19 using a screwdriver turn screw A until the flame setting is correct Normally for G30 gas fully tighten the adjustment screw LUBRICATING THE GAS TAP If a gas tap...

Page 18: ...liance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured GREEN YELLOW must be connected to the terminal in the plug whi...

Page 19: ...CE WITH EC DIRECTIVE 2002 96 EC At the end of its working life the product must not be disposed of as urban waste It must be taken to a special local authority differentiated waste collection centre o...

Page 20: ...Flush fitted hob front controls Continental Domestic Appliances Nottingham NG72SD 1101403 1 13...