14
TYPES OF GASES
There are two types of gas suitable to use with this appliance.
✓
G30 / G31
✓
G20
INSTALLATION
The appliance is set at the factory to operate with the gas indicated on the rating plate
on the appliance.
If the appliance must be operated with a gas different than that indicated on the plate,
it is necessary to make the following changes:
✓
gas connection
✓
replacement of the injectors
✓
regulating of the minimum flame.
GAS CONNECTION
Cat: II 2H3+
The connection must be executed by a suitably qualified person according to the rele-
vant standards.
The fitting (fig. 15a and 15b) is made up of:
✓
1 nipple “A”
✓
1 biconical gasket ring “B”
✓
1 elbow fitting “C”
✓
gasket “F”
GB
F
A
C
B
Figure 15a
Gas Section
F
A
C
F
Figure 15b