Features

One Control Unit can individually control three different Light Units.
 The light intensity can be manually controlled with a dial on the front panel, or externally 

controlled using Ethernet.
PWM control is used to control the light intensity at a frequency of 125 kHz.
TCP/IP and UDP/IP Ethernet communications can be used for external control.
External trigger inputs can be used to turn lights ON or OFF, or to strobe lights.
The Control Unit can be used for CCS LED Light Units with a voltage of 24 V and a 

power consumption of up to 28 W.

The total power consumption of the connected Light Units must be 28 W or less.

 

 INDEX

1.  Important Information for 

Equipment Safety

2.  Names and Functions of Parts
3.  Installation

4.  Connections

5.  What You Can Achieve with 

This Control Unit

6 . Manual Control
7 . Control with External Signals

 8.   Inputting an External Trigger

 9.   Troubleshooting

10.   Main Specifications

11.   Dimensions

12.   Optional Accessories

Environmental Regulation

Warranty Information

5

5

6

6

6

6

6

1
2
2

2

3
3
4

This Control Unit is specifically designed to control the light intensity of CCS 

LED Light Units.  It is mainly used to control LED Light Units that are used for 

machine vision and industrial inspections.

Instruction Guide

Control Unit for LED Light Units

PD3-3024-3-EI

With Ethernet communications

Thank you for purchasing a CCS product. 

To ensure proper use of the product, 

please read this Instruction Guide before 

use and keep it for your future reference.

Caution

INSTRUCTED

PROHIBITED

INSTRUCTED

PROHIBITED

INSTRUCTED

PROHIBITED

INSTRUCTED

PROHIBITED

INSTRUCTED

PROHIBITED

INSTRUCTED

PROHIBITED

INSTRUCTED

PROHIBITED

INSTRUCTED

INSTRUCTED

INSTRUCTED

PROHIBITED

The following symbols are used in this instruction guide to indicate and classify the 

relative importance of warnings and cautions.

The following symbols in the instruction guide indicate and classify the precautions.

WARNING

WARNING

Indicates that incorrect 
usage may result in 
serious injury or death.

Caution

Indicates that incorrect 
usage may result in injury 
or property damage.

PROHIBITED

PROHIBITED

DISASSEMBLY 

PROHIBITED

DISASSEMBLY 

PROHIBITED

DO NOT TOUCH 

WITH WET HANDS

DO NOT TOUCH 

WITH WET HANDS

These symbols mean 

the prohibited action.

These symbols indicate actions that 

must be performed.

DO NOT SUBJECT 

TO MOISTURE

DO NOT SUBJECT 

TO MOISTURE

INSTRUCTED

INSTRUCTED

UNPLUG

UNPLUG

This product has been designed with full consideration of safety. Incorrect 

usage of the product may result in fire, electric shock, or other serious 

damages. Observe the following precautions.

Do not touch the power cords during 

lightning. This may result in electric shock.

Do not disassemble or modify the product.

Doing so may result in fire or electric shock.

Do not touch the plugs or switches with wet 

hands. Doing so may result in electric shock.

Make sure that the product is free of 

moisture or any liquid. Doing so may result 

in fire or electric shock.

Before connecting or disconnecting cables, 

make sure that the power source is turned 

OFF. Not doing so may result in fire or 

electric shock.

If an abnormal condition occurs, such as 

fuming, heat, smell, or noise, stop using the 

product immediately, turn OFF the power 

source and unplug the power cord. Not 

doing so may result in fire or electric shock.

Do not use user-made branch cables. Doing 

so may cause product failure.

Do not place the product in direct sunlight or 

in a high-humidity environment. Doing so 

may result in fire due to internal temperature 

rise.

Always place the product on a stable and flat 

location. Doing so may result in the product 

falling or toppling, which may cause 

malfunction, accidents, or bodily injury.

Do not intentionally short-circuit the positive 

and negative output terminals.

Do not bend cables or jam them between 

objects when wiring. Doing so may cause 

product failure.

Do not wipe the product with volatiles such 

as paint thinner or benzene. Discoloration or 

deterioration of the product surfaces may 

occur.

Do not drop the product or subject it to 

impact. Doing so may cause product failure.

Use a dry cloth to remove dust or other 

foreign matter from the electrodes. Failure to 

do so may result in fire.

Do not connect any Light Units other than 

CCS LED Light Units. Doing so may cause 

overcurrent and the device may overheat or 

ignite.

Always use one of the following power cords. 

100 to 120 V range: SVT or SJT, AWG18, 

length: 3 m max., dielectric strength: 125 V min. 

200 to 240 V range: H05VV-F, AWG18, length: 

3 m max., dielectric strength: 250 V min.

Plug the power cord directly into an AC 

outlet. Using a power strip or connecting 

many loads from one electrical outlet may 

cause fire or electric shock.

Do not bundle product cables with 

high-voltage lines or power lines.

Allow leeway when installing the cables.

Always ground the power cord. Not doing so 

may cause product failure due to static 

electricity destroying electrical components 

including those in the Light Unit.

Use Light Units that are suitable for the 

product ratings. Exceeding the ratings may 

cause product failure.

Make sure that the length of the extension 

cable for light output is no longer than 5 m. 

If the extension cable is longer than 5 m, the 

voltage will drop due to the DC resistance of 

the cable, and the light intensity will 

decrease.

Do not disconnect the power cord or 

disassemble the product during operation. 

Pulling on the cable may damage the cable 

and result in fire or electric shock.

Before moving the product, disconnect all 

connection cables. Damaging the cables 

may result in fire or electric shock.

When mounting products in system racks or 

cases, do not insert the screws more than 

5 mm. Doing so may cause short-circuits in 

internal components.

1

Important Information for Equipment Safety

Read before Use

Reviews: