background image

rev. 2 – 09/06/2009

  

3/6 

 

DRAWING OF THE EQUIPMENT 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

CHARACTERISTICS 

 

Model Spits 

Chickens Width Depth Height Voltage Power 

E-6P 

700 mm 

360 mm 

530 mm 

230V~ 

2800 W 

E-8P-S2 

880 mm 

470 mm 

530 mm 

230V~ 

3500 W 

E-12P-S3 

12 

880 mm 

470 mm 

710 mm 

230V 3~ 

400V 3N~ 

5000 W 

 
 
 
 
 

 

INSTALLATION 

Installation, commissioning and repairs must only be carried out by a qualifed and approved service 
engineer , and with careful reference to the following instructions: 

Take the appliance out of its packaging. 

Remove the protection flm; in case of any residues of adhesive, use an appropriate   
solvent and then dry. 

The serial number label is set on the rear of the appliance and indicates  if the machine 
can be supplied with the available tension. The electrical connection must be in 
accordance with the stated requirements on the data plate fxed to the rear panel of the 
appliance. 

-            When the appliance is in operation ensure that the voltage does not vary from the fxed 
 

       value by more then +/-10%. 

According to the rules in force the equipment  installation must be done by an Omni 
polar switch between power grid and equipment with a contacts opening of at least 3 
mm. for each pole. The switch must be easily accessible.  

Make sure that the appliance is in a perfectly level position by regulating the feet, if 
necessary. 

Use an appropriate lagging by setting the appliance near infammable walls and 
furniture; fre prevention prescriptions must be followed very strictly. Leave a free space 
of at least 15 cm from infammable side walls and back. 

The equipment installation must be done in the respect of local prescriptions and 
according to the European rules in force. 

Fig. 1 