CB Tech WaterBox Operation Manual Download Page 20

Page 

20 

of 

20 

 

 

 

Product Warranty 

 

Carbon Block Technology,  Inc. warrants  its products to be free from defects  in material or workmanship  for a  period of  12 

months  from  delivery.  This  warranty  does  not  apply  to  replaceable  parts  or  components  subject  to  normal  wear  and 

replacement. 

 

Unless specifically  stated  in the  applicable  contract, the  warranty  excludes  any  claims  arising from  (i)  use  of the products 

in  a  manner  not  set  forth  in  the  written instructions  that  CB Tech  provides  with  the  product,  (ii)  any modifications  or 

damage  to the  product  not  made  or  caused  by CB Tech,  (iii)  non-compliance  with  state  and  local codes  or  ordinances  or 

other  special  codes  not  specifically  stated  in  writing  on  the  purchase  document  or  contract,  and  (iv)  performance  or 

results of the products.  

 

The customer’s sole and exclusive  remedy for breach of warranty concerning products will be repair or replacement of the 

defective portion thereof or a refund to the customer, in CB Tech’s sole discretion. Parts or components may be replaced as 
deemed necessary solely at CB Tech’s discretion, with the returnable part or components becoming the property of CB Tech, 

CB Tech would be responsible for any transportation and disposal of these parts, CB Tech does not warrant that products will 

operate uninterrupted or error free or that non-material defects will be corrected. This warranty does not apply to any defect 

caused by: failure of the user to provide a suitable operating environment, use of products for a purpose or in a manner other 

than that, for which they were designed, or any other abuse, misuse, or neglect of the products. 

 

EXCEPT FOR THESE EXPRESS WARRANTIES, TO THE EXTENT PERMITTED BY APPLICABLE LAW, CARBON 

BLOCK TECHNOLOGY, ITS SUPPLIERS, LICENSORS, AND REPRESENTATIVES SPECIFICALLY DISCLAIM ALL 

OTHER  WARRANTIES,  EXPRESS  OR  IMPLIED,  IN  FACT  OR  BY  LAW,  INCLUDING,  BUT  NOT  LIMITED  TO, 

ANY  IMPLIED  WARRANTY  OF  MERCHANTABILITY,  QUALITY,  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE 

AND NONINFRINGMENT. 

 

IN  NO  EVENT  WILL  CB  TECH  OR  ITS  SUPPLIERS,  LICENSORS,  OR  REPRESENTATIVES  BE  LIABLE  TO  THE 

CUSTOMER  OR  ANYONE  ELSE,  FOR  INDERECT,  SPECIAL,  INCIDENTAL,  PUNITIVE,  OR  CONSEQUENTIAL 

DAMAGES  OR  FOR  LOST  PROFITS  OR  REVENUE,  LOSS  OF  USE  OF  THE  PRODUCTS  OR  RELATED 

MATERIALS,  LOSS  OF  DATA,  THE  COST  OF  RECOVERING  SUCH  PRODUCTS,  RELATED  MATERIALS  OR 

DATA OR, THE COST OF ANY SUBSTITUTE PRODUCTS OR MATERIALS, ARISING FROM ANY BREACH, OR 

THE  SALE,  LICENSE,  USE  OF,  OR  INABILITY  TO  USE  THE  PRODUCTS,  OR  RELATED  MATERIALS,  EVEN  IF 

ADVISED  OF  THE  POSSIBILITY  OF  SUCH  DAMAGES,  REGARDLESS  OF  THE  FORM  OF  ACTION,  WHETHER 

CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT PRODUCT LIABILITY, OR OTHERWISE. 

 

In no event shall CB Tech’s aggregate liability arising in connection with a product exceed the price paid to CB Tech for 
such product.

 

Summary of Contents for WaterBox

Page 1: ...e 1 of 20 CB Tech WaterBox Mobile Water Filtration System Operation Manual CB Tech Tel 866 622 9373 7251 Cathedral Rock Drive www CarbonBlockTech com Las Vegas NV 89128 sale CarbonBlockTech com 01411...

Page 2: ...PLUG TO AC POWER CABLE CONNECT GFI PLUG TO POWER SOURCE PRESS TEST BUTTON TO VERIFY GFI FUNCTION THEN PRESS RESET CONNECT 12V 24V DC POWER CABLE ATTACH POWER CABLE TO BATTERY OR USE 12 VDC CIGARETTE L...

Page 3: ...BOTH WATER INTAKES ARE FREE FROM OBSTRUCTION 3 CHECK ALL HOSE CONNECTIONS BETWEEN PUMP AND WATER SOURCE FOR LEAKS APPLY PETROL GEL TO O RINGS IF NECESSARY 4 CONFIRM PUMP INLET STRAINER IS CLEAR OF DEB...

Page 4: ...ns 5 IV Technical Specifications 6 V System Overview 7 VI Using the CB Tech WaterBox Filtration System 8 A Unpacking 8 B Power Connections 9 C Operating the CB Tech WaterBox 11 D Maintaining the CB Te...

Page 5: ...ght or heat are necessary The CB Tech WaterBox has been tested by NSF International and received a letter of compliance from the United States Public Health Command certifying it has met the straight...

Page 6: ...cm x 60 2 cm x 33 3 cm Electrical requirements Voltage 12 24 VDC or 120 230 VAC Maximum height above water Priming 8 ft 2 4 m Operating 20 ft 6 1 m Safe to run pump dry Yes Temperature range Dry Stora...

Page 7: ...er Outlet Port 16 230 VAC GFI Plug 5 Filter Housing Wrench 17 120 VAC GFI Plug 6 Pressure Gauge 18 Component Storage Bag 7 Pump Intake Strainer 19 Hose Intake Adaptor 8 Pump 20 Hose Intake Float 9 Vol...

Page 8: ...is has the following parts 25 of 3 8 wire reinforced intake hose 10 of 3 8 wire reinforced outlet hose 2 CB Tech Nanomesh Stage II filter cartridge 1installed 1 spare 5 CB Tech Nanomesh Stage I filter...

Page 9: ...lti voltage power supply Figure 2 contains two voltage converters one for switching 120 VAC 230 VAC to 12 VDC and other for switching 24 VDC to 12 VDC Only one voltage converter operates at a time dep...

Page 10: ...lug from receptacle and allowing protective cap to close CAUTION Verify power source voltage prior to the connection with the multi voltage power supply only Figure 2 DC Power cable connection connect...

Page 11: ...epeated every time the power source is disconnected to verify GFI functionality and reduce the possibility of electrical shock hazards for users CAUTION Although the CB Tech WaterBox is fitted with GF...

Page 12: ...confirm that the pump intake strainer is in place and free of debris Figure 6 The pump intake strainer must be in place when operating the CB Tech WaterBox to prevent debris from entering the pump and...

Page 13: ...lter housing 1 This information will be needed to decide when the filters need to be changed OPERATIONAL NOTES It is normal to observe a small amount of black powder in the filtrate during the initial...

Page 14: ...water at ground level 6 Turn on the WaterBox press the pressure relief valve on the first Stage I filter housing to purge the air and allow the line to be primed All air must be purged from the line...

Page 15: ...Figure 9 c Insert cartridge in the housing with the two O rings toward the top The cartridge should seat itself easily in the filter housing assembly d Rinse any particulate debris out of the filter...

Page 16: ...decreases by 10 psi below the initial starting pressure Therefore it is important to make a note of the initial pressure reading on the system pressure gauge A typical initial pressure reading should...

Page 17: ...continues to trip confirm that the power source is operating at the selected voltage 12 VDC 24 VDC 115 VAC or 230 VAC If the power source is operating correctly and the circuit breaker continues to tr...

Page 18: ...e outlet hose and water intake are free from obstruction Confirm that pump inlet strainer is clear of debris If clogged unscrew cap remove and wash mesh screen Check all plumbing connections for leaks...

Page 19: ...AAs Organophosphates pesticides and herbicides Total Organic Carbon TOC Volatile Organic Compounds VOCs Customer Feedback Detailed feedback from users in the field on the performance of the CB Tech Wa...

Page 20: ...ed or error free or that non material defects will be corrected This warranty does not apply to any defect caused by failure of the user to provide a suitable operating environment use of products for...

Reviews: