CZR-HD1002

Natural Gas /LPG

70g

Semiconductor

70mm * 70mm * 28mm

Natural diffusion

DC5V±0.1V

0-20% LEL

100s

5%LEL

Visible and Audible alarm

Temperature: -20 to 40 
Humidity: ≤ 95% RH (no frost)

85dB

5 years

Model

Applicable Gas

Weight

Overall Dimensions

Sampling Method

Working Voltage

Range

Self-test Time

Alarm presetting 
level

Alarm

Working 
Environment

Alarm Volume

Lifespan

Sensor Type

5

6

Failure

Phenomenon

The connection 

of the power cord 

is not well

Power indicator

 has failed

Press the self-test 

button without 

sound and 

light alarm

Circuit failure

No response 

to detection 

of gas

Pre-boot program 

has not over yet

Circuit failure

After the 
pre-start 

procedure, 

the detector has 

been in the 

alarm state

There are large 

amount of volatile 

organic compounds

 surround

Place the 

detector 

in a clean 

air environment 

andrestart the 

self-test 

program

Long storage

Circuit failure

Please check

 thepower cord

 connection and  

connect it again

Please contact 

the seller for 

assistance

Please contact 

the seller for 

assistance

Wait for the 

program to 

complete the 

pre-boot

Please contact 

the seller for 

assistance

Please contact

 the seller for 

assistance

Continue to 
aging it with 
electricity

The green power 

indicator does 

not light

7

MainSpecifications

Commonfaultsandsolutions

FailureAnalysis

Solutions

After-sales service and Warranty Policy

4

EquipmentMaintenance

1.First time to use: Please aging it with electricity for more than 24

hours when first to be used after a long-distance transport or long

storagesothatitcankeepthebestperformance.

2.Self-checking period: Please self-test it for every 4-6 months.When

youuseanknownconcentrationofgastotestthedetectortoconfirm

whether it will work, please be sure the operation environment is

absolutelysafe!

3.Cleaning:Pleaseusesoftbrush,velvetcleaningtoolstocleanitsface

end's dust or oil to ensure its detection hole breathable so that can

keep good display.Please do not use detergents, bleach or other

cleaningliquidtocleanit.

4.Indoor use only: Please avoid rain or moisture when use it. Please

avoiditfalldown.Donotbeat,openorchangeit,oritmightcausesthe

productfailure.

6.Lifespan:Themaximumlifeofthedetectoris5yearsundernormal

situation.Pleasereplaceanewonewhenovertheuseoftheperiod.

5.Avoid volatile substances surround: Please do not use volatile

substanceslikealcoholorhairgelneartothedetector.Ifthiskindof

material causes the false report of the detector, please ventilates

promptlysothatitcanreturntothenormalexaminationcondition.

SUPPORT ONE-YEAR FREE REPLACEMENT,BUT CAN NOT ENJOY 
THE WARRANTY UNDER THE SITUATION OF NON-NORMAL USE
(FOR EXAMPLE: LIGHTNING, VOLTAGE INSTABILITY, WATER AND 
OTHER HUMAN FACTORS)

Reviews: