background image

16

7. Test function:
After installation, and at least once per quarter, test all of your alarms to ensure 

they are operating correctly and are within range of each other.
It is recommended to check visually every week if the LED flashes correctly 

(every 48sec.)
Press the test button on any alarm for at least 6.5 seconds (count 2 sets of 

3 sound sweeps). This will send out a test signal from the alarm; all other 

connected alarms should receive the signal within a short time. The alarms will 

emit a short beep and the LED will flash every 8 seconds for 2 minutes.
You can also conduct the interconnection test through the CAVIUS App 

(if you have the GATEWAY HUB and App set up).

Summary of Contents for 2107-001

Page 1: ...PLEASE READ THIS USER GUIDE CAREFULLY PHOTOELECTRIC SMOKE ALARM THE WORLD S SMALLEST ...

Page 2: ... INSTALLATION AND RETAIN FOR FUTURE USE CAVIUS Photoelectric Smoke Alarm Part Code 2107 002 10022 10026 Model 2107 001 Recess Kit Part Code 11014 For large text option and maintenance guide visit cavius co nz resources or cavius com au resources ...

Page 3: ...smoke alarm _________________________________________________ 12 Test function ______________________________________________________________ 16 Normal mode______________________________________________________________ 18 Alarm mode_______________________________________________________________ 18 Hush function _____________________________________________________________ 19 Add extra device _____...

Page 4: ... a house group are 32 Please note These must be alarms from the CAVIUS Wireless Family range The distance between interconnected alarms depends on the house layout and they should always be tested after installation It is not advised to be more than 10m distance between two alarms Diameter 78mm Height 43mm 2 ...

Page 5: ...The alarm is powered by two 3v CR123A lithium batteries Interconnected by RF 926 365 MHz Complies to standards AS3786 2014 RCM 3 Alarm condition aural signal pattern according to ISO 8201 ...

Page 6: ...1 The best areas to install an alarm Install alarms on each floor of the house in hallways and stairways Alarms in each room such as bedrooms and living rooms 4 ...

Page 7: ... of where a ceiling and wall join In rooms where the temperature goes outside 4c to 38c or above 90 relative humidity not condensing In kitchens garages laundries or too close to fireplaces areas where either dampness gases or heat could occur Place the alarm where it is reachable in order to test the battery and for maintenance 5 ...

Page 8: ... Placement The smoke alarm is designed to be installed on a ceiling preferred or wall Ceiling installation The smoke alarm should be a minimum of 50cm from the wall 6 Minimum 50cm from peak Ceiling Wall ...

Page 9: ...tion For cathedral or peak ceiling a minimum of 50cm from the peak 7 M i n i m u m 5 0 c m f r o m p e a k Ceiling Ceiling For wall installation a minimum of 30cm and maximum of 50cm from the ceiling Minimum 30cm and maximum 50cm from ceiling Wall ...

Page 10: ...d connect alarms without GATEWAY HUB or App All alarms that need to be connected in the house should be put into Link Mode by sliding the switch on the back of the alarm to the Link Mode position 8 LINK MODE NORMAL MODE ...

Page 11: ... one alarm only This alarm will become the Master and will start sending out a specific house code to the other alarms take note of which alarm is the Master you may need this for adding extra devices in future The red LED will flash ...

Page 12: ...10 As the other alarms receive the specific house code they will also flash the LED light When all alarms flash the red LED they are connected and can be switched out of Link Mode and installed ...

Page 13: ... Ensure the CAVIUS GATEWAY HUB is plugged into your router and the wall socket Download the CAVIUS App from the Apple App Store or Google Play Launch the app from your smart phone or tablet and just follow the instructions for setting up your alarms GATEWAY HUB ROUTER ...

Page 14: ... HOLES WITH A PEN 6 Installation of smoke alarm Info The label on the product must not be removed due to important information Option 1 Standard base 1 Use the mounting base ring to mark the screw holes on the ceiling ...

Page 15: ...13 USE THE ENCLOSED SCREWS AND PLUGS FOR INSTALLATION CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE ...

Page 16: ...14 Option 2 Recess Kit 1 Place the Cover Ring on the area where you wish to install the smoke alarm trace around the inside of the ring HOLE SAW DRILL REQUIRED 81mm 85mm ...

Page 17: ...CE COVER RING AROUND THE RECESS KIT MOUNTING BASE CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE 2 Using your hole saw 81mm 85mm cut a hole into the surface CAUTION Ensure there is no wiring or any electrical equipment behind the surface you are drilling your hole into ...

Page 18: ... correctly every 48sec Press the test button on any alarm for at least 6 5 seconds count 2 sets of 3 sound sweeps This will send out a test signal from the alarm all other connected alarms should receive the signal within a short time The alarms will emit a short beep and the LED will flash every 8 seconds for 2 minutes You can also conduct the interconnection test through the CAVIUS App if you ha...

Page 19: ...aned by running the vacuum on a low setting around the smoke alarm chamber and tested again Once the alarms have indicated they are interconnected the beeps can be stopped on each alarm with a short press of the test button TIP It is safe to cover the sound output hole with your finger during the testing to minimise the sound level emitted If any problems occur during testing visit www cavius co n...

Page 20: ...It will sound the alarm signal and the LED will flash Please note that only the source alarm s LED will flash so it can be identified The smoke alarm will also transmit the alarm signal to the other connected alarms which will also sound the alarm signal after a short delay A notification will be sent to your smartphone or tablet through the CAVIUS App if you have the GATEWAY HUB and App set up ...

Page 21: ...e test button on the originating smoke alarm only indicated by the flashing LED You can hush each alarm individually however the source alarm will continue to sound until hushed The reason for this is that it is necessary to locate the source of the alarm before using the hush function This is to make sure that it is not a life threat ening situation ...

Page 22: ...means that the wireless system can consist of a combination of smoke alarms heat alarms and security products Just place the Master and new device into Link Mode repeat Section 4 If using the CAVIUS App just follow the instructions in the app on how to set up a new device Always test connection to all devices by repeating the test function Section 7 after adding devices ...

Page 23: ...its life In this stage it will continue for a minimum of 30 days You must replace the smoke alarm after 10 years of use or if the smoke alarm has suffered any damage The smoke alarm is not active unless it is clicked into the mounting base Always test the smoke alarm after clicking into the mounting base allow 5 seconds before testing ...

Page 24: ...IUS smoke alarm is a photoelectric smoke alarm Alarm signal Fire alarm activation is indicated by a series of repeated tones The minimum sound level is 85 dB at 3 metres Battery Powered by two non replaceable 3v CR123A 1600mAh lithium batteries ...

Page 25: ...lkeborg cavius com info cavius com Manufactured in P R C Distributor information for New Zealand CAVIUS Nano Ltd 58a Poplar Lane Papamoa 3187 NZ www cavius co nz for Australia CAVIUS Australia 14 30 Octal Street Yatala QLD 4207 Australia www cavius com au ...

Page 26: ...damage neglect unauthorised deconstruction or dismantling and any airborne or other contamination however this may have occurred If this product has an acknowledged defect it must be returned to the national CAVIUS Distributor at the purchasers cost with the proof of purchase If the product has become defective within the 10 year warranty CAVIUS APS Denmark will repair or replace the unit without ...

Page 27: ...dio spectrum pollution comprises transmissions inside the band allocated for alarm devices such as the CAVIUS devices Such transmissions may activate the receiver inside the devices for a longer time than is normal in standby This is not a specific problem for CAVIUS devices but for all similar radio linked technology powered by batteries The limited warranty will not cover the battery life period...

Page 28: ...PLEASE READ THIS USER GUIDE CAREFULLY PHOTOELECTRIC SMOKE ALARM THE WORLD S SMALLEST ...

Reviews: