Alarm signal 2  (-  -  -)  is  a  non  life  threatening 

alarm, like a flooding alarm:

Smoke alarm signal:             --- --- ---

Heat alarm signal:                --- --- ---

Flood alarm signal:               -    -   -
Please note that only the originating alarm’s LED 

will flash, so it can be identified. 
9. PAUSE/HUSH FUNCTION:
If the smoke alarms are to set into a false alarm 

by cooking, fireplace, etc. they can be paused for 

10 minutes by pressing the test button on the 

originating smoke alarm only (indicated by the 

flashing LED).
The reason of this is that it is necessary to locate 

the source of the alarm before using the hush 

function.  This is to make sure that it is not a life 

threatening situation. 
10.  ADD EXTRA DEVICE:
All CAVIUS interconnected alarms within the 

can be added to the system as 

they run on the same frequency and use the same 

data protocol.This means that the wireless system 

can consist of a combination of smoke, heat, flood 

etc.
Place all alarms into ‘Learn Mode’ and repeat 

section 1.
Always test connection to all devices by repeating 

test function section 6 after adding devices.
11. LOW BATTERY SIGNAL:
Your product has a 5Y battery life.

When the battery is starting its end of life, a short 

beep will sound out every 48 seconds for 30 days.
The alarm affected by the low battery will only 

beep, no other connected alarms will sound.
It is safe to change batteries in the alarms without 

going through the learn process again – they will 

not forget the codes during the battery change 

process. 
12. BATTERY REPLACEMENT:
To replace the battery, detach the smoke alarm 

from the mounting base by twisting counterclockwise. 

Replace the battery respecting the polarities.
Caution: There is a risk of explosion if the batteries 

are replaced by an incorrect type.
Attach the alarm in the mounting base by twisting 

clockwise until it clicks, and test the alarm.

13. MAINTENANCE & TROUBLE SHOOTING:
• The smoke alarm should be vacuum cleaned 

once per quarter, to remove dust particles, and 

it can be wiped with a damp cloth. (Do not open 

the alarm).

 • High humidity condensing which can be 

resolved by drying the smoke alarm.

If the smoke alarm does not work when the test 

button is pushed, the probable cause is a faulty 

battery. Check if the battery is worn out and re-

place it. Always test the alarm after replace-

ment of battery.
If the problem continues, please visit www.cavius.

com for any trouble shooting. 
14. OTHER INFORMATION:
Do not paint the alarm.
Disposal: For battery and product, please dispose 

properly at the end of life. This is electronic waste 

which should be recycled.

Please note local regulations about information 

to your insurance company regarding installed 

smoke alarms. 
Complies to the Radio Equipment Directive 

2014/53/EU
RF Frequency: 868 MHz.
Maximum radio-frequency power transmitted: 20 

dBm.
Full DoC to 2014/53/EU (RED) can be download-

ed at www.cavius.com.
WARNING: All alarms should be assumed as due 

to actual fire and the dwelling should be evacuat-

ed immediately.
WARNING: To prevent injury, this apparatus must 

be permanently fixed to the ceiling/wall in accor-

dance with the installation instructions.    
WARNING: Batteries shall not be exposed to ex-

cessive heat such as shine, fire, or the like.  Note 

the local country regulations regarding installa-

tion.
The  CE  mark  affixed  to  the  product  confirms 

compliance with all relevant European directives 

and harmonized requirements in the EN14604 

standard and Construction Products Regulation 

(CPR) 305/2011 along with the Radio Equipment 

Directive (RED) 2014/53/EU for all wireless family 

products. 

All Rights reserved: CAVIUS assumes no responsi-

bility for any errors, which may appear in this manu-

al. Furthermore, CAVIUS reserves the right to alter 

the hardware, software, and/or specifications de-

tailed herein at any time without notice, and CAVI-

US does not make any commitment to update the 

infor mation contained herein. 

Developed by CAVIUS 

Jens Juuls Vej 28 K, DK-8260  

Manufactured in P.R.C.

Once the mounting base is installed, attach the 

alarm by twisting clockwise until it clicks. If the bat-

tery is either missing or inserted incorrectly, or the 

switch is in ‘Learn Mode’, the smoke alarm will not 

be able to click into the mounting base. 

6. TEST FUNCTION:
After installation, and at least once per quarter, 

test all of your alarms to ensure they are operating 

correctly and are within range of each other.
It is recommended to check visually every week if 

the LED flashes correctly (every 48sec.)
Press the test button on any alarm for at least 10 

seconds. This will send out a test signal from the 

alarm; all other connected alarms should receive 

the signal within a short time. The alarms will 

emit a short beep and the LED will flash every 8 

seconds for 2 minutes. 
NOTE: Test function also allows to send a deplet-

ed RF signal to ensure an optimal operation in 

normal conditions.
When the test signal is sent out, the alarms will 

respond in two ways:
1. A single beep every 8 seconds indicates that the 

alarms are connected and functioning.
2. Three short beeps every 8 seconds indicates a 

smoke sensor fault. The alarm should be cleaned 

by running the vacuum (on a low setting) around 

the smoke alarm chamber and tested again.
If required this indication can be stopped early on 

each alarm by a short press of the test button. 
TIP: It is safe to cover the sound output hole with 

your  finger  during  the  testing  to  minimize  the 

sound level emitted. 
If the problem continues, please visit www.cavius.

com for any trouble shooting. 
7. NORMAL MODE:
In normal mode the LED will flash every 48 seconds 

to show correct operation.
8.  ALARM MODE:
When a concentration of smoke is detected, the 

smoke alarm will go into ‘Alarm Mode’. It will 

sound the alarm signal and the LED will flash. 
The smoke alarm will also transmit the alarm sig-

nal to the other connected alarms, which will also 

sound the alarm signal after a short delay.
The CAVIUS Wireless Family have two different 

alarm signals: 
Alarm signal 1  (---  ---  ---)  is  life  threatening 

alarms, like a smoke alarm. 

CLICK THE SMOKE 

ALARM FIRMLY INTO THE 

BASE TO LOCK

127786 rev12

EN 14604:2005 + AC :2008 

DoP no.: 2103

1116

21

The CE and RED declaration of conformity and DoP can be downloaded from: http//www.cavius.com

The paper version of the DoP is available free of charge upon request.

Declared performance 4.1-4.19 + 5.2-5.24: Passed.

©2022 Carrier. All Rights Reserved. 

All trademarks and service marks referred herein are property of their respective owners.

Reviews: