7. Normal mode:
In normal mode the LED will flash every 48 seconds to show the alarm is 

functioning.
8.  Alarm mode:
When a concentration of smoke is detected, the smoke alarm will go into 

‘Alarm Mode’. It will sound the alarm signal and the LED will flash. Please note 

that only the source alarm’s LED will flash, so it can be identified.
The smoke alarm will also transmit the alarm signal to the other connected 

alarms, which will also sound the alarm signal after a short delay.

9. Hush function:
If the smoke alarms are to set into a false alarm by cooking, fireplace, etc. 

all of them can be paused for 10 minutes by pressing the test button on the 

originating smoke alarm only (indicated by the flashing LED). 
You can hush each alarm individually, however the source alarm will continue 

to sound until hushed.
The reason for this is that it is necessary to locate the source of the alarm 

before using the hush function. This is to make sure that it is not a life 

threat ening  situation.

Summary of Contents for 10022

Page 1: ...PLEASE READ THIS USER GUIDE CAREFULLY PHOTOELECTRIC SMOKE ALARM THE WORLD S SMALLEST ...

Page 2: ...resources or cavius com au resources 1 TECHNICAL INFORMATION The maximum number of CAVIUS Wireless Family alarms that can be interconnected within a house group are 32 Please note These must be alarms from the CAVIUS Wireless Family range The distance between interconnected alarms depends on the house layout and they should always be tested after installation It is not advised to be more than 10m ...

Page 3: ...d by RF 926 365 MHz Complies to standards AS3786 2014 RCM Alarm condition aural signal pattern according to ISO 8201 1 The best areas to install an alarm Install alarms on each floor of the house in hallways and stairways Alarms in each room such as bedrooms and living rooms ...

Page 4: ...lative humidity not condensing In kitchens garages laundries or too close to fireplaces areas where either dampness gases or heat could occur Place the alarm where it is reachable in order to test the battery and for maintenance 4 5 3 Placement The smoke alarm is designed to be installed on a ceiling preferred or wall Ceiling installation The smoke alarm should be a minimum of 50cm from the wall M...

Page 5: ... k Ceiling Ceiling For wall installation a minimum of 30cm and maximum of 50cm from the ceiling Minimum 30cm and maximum 50cm from ceiling Wall 4 How to set up and connect alarms All alarms that need to be connected in the house should be put into Link Mode by sliding the switch on the back of the alarm to the Link Mode position LINK MODE NORMAL MODE ...

Page 6: ...d LED will flash As the other alarms receive the specific house code they will also flash the LED light When all alarms flash the red LED they are connected and can be switched out of Link Mode and installed Remove the Safety lock from the mounting base Place the Safety lock into the slot once the alarm has been clicked into the base To remove the Safety lock in future you will require a screwdriv...

Page 7: ...o The label on the product must not be removed due to important information Option 1 Standard base 1 Use the mounting base ring to mark the screw holes on the ceiling USE THE ENCLOSED SCREWS AND PLUGS FOR INSTALLATION CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE ...

Page 8: ...TO THE HOLE AND SECURE WITH SCREWS PLACE COVER RING AROUND THE RECESS KIT MOUNTING BASE CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE 2 Using your hole saw 81mm 85mm cut a hole into the surface CAUTION Ensure there is no wiring or any electrical equipment behind the surface you are drilling your hole into NOTE The Safety lock cannot be used when installing the alarm with the Recess Kit ba...

Page 9: ...every 8 seconds for 2 minutes When the test signal is sent out the alarms will respond in two ways 1 A single beep every 8 seconds indicates that the alarms are connected and functioning 2 Three short beeps every 8 seconds indicates a smoke sensor fault The alarm should be cleaned by running the vacuum on a low setting around the smoke alarm chamber and tested again Once the alarms have indicated ...

Page 10: ...to the other connected alarms which will also sound the alarm signal after a short delay 9 Hush function If the smoke alarms are to set into a false alarm by cooking fireplace etc all of them can be paused for 10 minutes by pressing the test button on the originating smoke alarm only indicated by the flashing LED You can hush each alarm individually however the source alarm will continue to sound ...

Page 11: ...n to all devices by repeating the test function Section 7 after adding alarms 19 18 Low battery indicator A short acoustic beep will sound and the LED will flash every 48 seconds when the battery is near the end of its life In this stage it will continue for a minimum of 30 days You must replace the smoke alarm after 10 years of use or if the smoke alarm has suffered any damage The smoke alarm is ...

Page 12: ...85 dB at 3 metres Battery Powered by two non replaceable 3v CR123A 1600mAh lithium batteries Developed Manufactured by Aps Julsøvej 16 DK8600 Silkeborg cavius com info cavius com Manufactured in P R C Distributor information for New Zealand CAVIUS Nano Ltd 58a Poplar Lane Papamoa 3187 NZ www cavius co nz for Australia CAVIUS Australia 14 30 Octal Street Yatala QLD 4207 Australia www cavius com au ...

Page 13: ... cost The guarantee excludes labour costs freight costs service costs and any incidental and consequential damages Do not attempt to repair or service this product as this will invalidate the warranty Under some unusual circumstances the presence of high levels of radio spectrum pollution may result in the batteries within the CAVIUS device not lasting as indicated in the product sheet Radio spect...

Page 14: ...PLEASE READ THIS USER GUIDE CAREFULLY PHOTOELECTRIC SMOKE ALARM THE WORLD S SMALLEST ...