5.0 OPERATION
The CaviBlaster
®
2828-E60 should be operated by two (2) properly trained individuals.
One, the diver, operates the zero-thrust gun, while the other operates the power unit. Both
operators should be in audio or visual communication with each other.
The CaviBlaster
®
2828-E60 should only be operated by
properly trained personnel who are familiar with the
contents
of
the
manual.
Review
the
safety
requirements found in Section 3.0 before operating.
5.1 Preparing the CaviBlaster
®
for Operation
The following checklist should be completed in advance, so that the unit is always
ready for immediate use. This should also be completed after each use.
1) Inspect the CaviBlaster
®
power unit, electric power cord, hoses, JIC fittings
and gun for any signs of damage.
2) Check that the motor is clean and ventilation openings are clear.
3) Inspect the inline strainer and filter media, to ensure that neither are clogged
(See Figure 6.1). Clean or replace as necessary.
4) Check
for proper pressure pump oil level (See pump Owner’s Manual found
in the
Appendix
). Add oil (SAE 30 non-detergent) if necessary.
5.2 Startup of the CaviBlaster
®
Before starting the CaviBlaster
®
2828-E60 power unit, review all safety
requirements found in Section
3.0
SAFETY INFORMATION
. This equipment
should only be operated by individuals who have read and understand the
CaviBlaster
®
Operation and Maintenance Manual.
1) Verify that the unit has been properly prepared for operation as described
in Section 4.