Figure 4.3
– Gravity Feeding Source
a) Using the Feed Pump System:
•
Verify the main power switch, HPP motor switch and feed pump motor are
switched to OFF.
•
Ensure the E-Stop button
is ‘
Pushed In
’ so that the power supply has been
disconnected. (See Figure 2.2).
•
Connect the cam-lock socket on the 1-1/2
” clear PVC feed hose to the water
inlet connection on the control panel (See Figure 2.2). Place the other end of
the hose in the water supply.
•
THE PUMP SYSTEM MUST BE FULLY PRIMED BEFORE STARTING THE
HPP PUMP OR SERIOUS DAMAGE TO HPP PUMP WILL OCCUR. REFER
TO SECTION 4.3.2 (ABOVE) FOR PRIMING INSTRUCTIONS.
b) Using Force Feed Supply from an alternate source:
•
Verify the main power switch, HPP motor switch and feed pump motor are
switched to OFF.
•
Ensure the E-Stop button
is ‘
Pushed In
’ so that the power supply has been
disconnected. (See Figure 2.2).
•
When feeding the CaviBlaster
®
with an alternate water source,
the source must
be capable to supply water at a volume of greater than 28 gallons per minute
(106 LPM) at a maximum pressure of 50-psi.
•
Connect a 1-
1/2” cam-lock socket on the water supply hose to the water inlet
connection on the control panel (See Figure 2.2). Confirm system is primed.
Water level
Pump inlet must be
below the tank outlet