CAVIDYNE Caviblaster 1222-E60 Operation & Maintenance Manual Download Page 6

2.

If   using   a   pressure   gauge   located   on   the
CaviBlaster

TM

  power   unit,   the   water   is   adjusted   as

described in step 1 above.   However, pressure will
need to be higher to account for sidewall friction loss
in   the   pressure   hose.     The   pressure   at   the   pump
should   be   2,200-psi   plus   0.75-psi   per   foot   of
thermoplastic pressure hose.   For example, if using
the CaviBlaster

TM

 with 100 feet of pressure hose, the

pressure   gauge   located   next   to   the   pump   should
indicate 2,275-psi.  Pressure adjustments are made in
the same manner as described above.   

There should

always be a trickle of water through the bypass when
the Zero Thrust Gun trigger is in the open or “ON”
position.

Figure 10

3.

If adjusting the CaviBlaster

TM

 without a pressure 

gauge, close the pressure-regulating unloader  until
there is just a trickle of water (less than ¼ gallon or 1
liter per minute)  coming  out of the bypass  with the
Zero Thrust Gun trigger in the open or “ON” position.

Shutting down the CaviBlaster

TM

 power unit:

1. Stop the motor by depressing the red “STOP” button (Figure 8) on the motor controller.

2. Shut off the supply of water to the pump.

3.

Squeeze the Zero Thrust Gun trigger to the open or “ON” position (Figure 9) to release the
water pressure remaining in the hose(s) 

while the Zero Thrust Gun is submerged

.

4. It is now safe to remove the Zero Thrust Gun from the water.

5. Flush the system and rinse the power unit with fresh water at the end of the day.

Maintenance of the CaviBlaster

TM

 unit:

1. Empty and clean the inline strainer every day.

2. Check the pressure pump oil level and consistency every day.

3. Flush the system and rinse the power unit with fresh water after each days use.

4. Inspect the pump drive belt every week and replace the belt when cracking appears.

Page - 6

For more information please email [email protected] or call 1-(352)275-5319

Summary of Contents for Caviblaster 1222-E60

Page 1: ...Model 1222 E60 Operation Maintenance Manual www cavidyne com ...

Page 2: ... 2 Figure 3 5 To supply water to the CaviBlasterTM power unit connect a 1 25 mm diameter feed hose to the cam lock plug on the inline strainer inlet Figure 4 Either fresh water or seawater can be used with this system The water source must supply the CaviBlasterTM with water at a volume of greater than 12 gallons 45 liters per minute at a maximum pressure of 70 psi 5 bar Ensure that the feed hose ...

Page 3: ...pressure hose to the quick connect plug under the pressure regulating unloader Figure 6 The high pressure hose has a brass quick connect socket on the end The 1222 E CaviBlasterTM can deliver the required pressure utilizing up to 300 feet 100 meters of diameter rubber hose or 600 feet 200 meters of thermoplastic hose Using greater lengths or smaller diameters of hose may degrade performance If gre...

Page 4: ...to start the motor 10 The system is now ready to operate refer to photo on cover for overall system set up Figure 8 Figure 9 WARNING Although the CaviBlasterTM system is safe to use when submerged in water the system generates a high pressure up to 2 200 psi water stream which can cause injury when the Zero Thrust Gun is out of the water ALWAYS keep the Zero Thrust Gun submerged when the pressure ...

Page 5: ...g 6 Ensure that the Zero Thrust Gun is submerged any time the motor and pressure pump are operating Adjusting the CaviBlasterTM system for maximum performance 1 If using a calibration pressure gauge situated between the pressure hose and the CaviBlasterTM Zero Thrust Gun the water pressure should be 2 200 psi with the Zero Thrust Gun submerged and the Zero Thrust Gun trigger in the open or ON posi...

Page 6: ...ss than gallon or 1 liter per minute coming out of the bypass with the Zero Thrust Gun trigger in the open or ON position Shutting down the CaviBlasterTM power unit 1 Stop the motor by depressing the red STOP button Figure 8 on the motor controller 2 Shut off the supply of water to the pump 3 Squeeze the Zero Thrust Gun trigger to the open or ON position Figure 9 to release the water pressure rema...

Page 7: ...e power source 6 Make sure that the diver is ready to work and that the Zero Thrust Gun is submerged in the water Apply hearing protection if the diver is not wearing a helmet 7 Start the motor 8 Activate the cleaning cavitation stream by squeezing the Zero Thrust Gun trigger to open or ON 9 Proceed with cleaning 10 Stop the motor 11 Shut off the water supply to the pump 12 Release pressure from t...

Page 8: ...n particular to the nails The gloves will absorb most of the energy produced by bursting cavitation bubbles and prevent the cavitation bubbles from contacting the operators hands The gloves will also protect operators hands from the initial shockwave when the Zero Thrust Gun is activated Serious harm and injury may result from the misuse of CaviBlasterTM system equipment or improperly selected fit...

Reviews: