Starting the CaviBlaster® power unit:
1. Start the feed pump and place in one feet of water, at the water source.
2. Ensure that the system is primed with water and that there are no leaks in the
system. The pressure pump is a positive displacement pump and water must be
supplied under pressure. Failure to pump feed water to the pressure pump will
result in damage to the pump.
3. Connect the 3/8″ high
-pressure hose to the quick-connect plug under the
pressure-regulating unloader (Figure-11). The high-pressure hose has a brass quick-
connect socket on the end. The CaviBlaster® Model 0625-G can deliver the required
pressure utilizing up to 300 feet of 3/8″ diameter rubber hose.
Connect HP Hose to the quick connect under pressure regulator - Figure #11
4. Move throttle to the On position (figure 12) and fully engage choke (figure 13)
and then turn the key to start engine (figure 14).
Throttle at the On position - Figure #12 Fully engage Choke - Figure #13 Ignition key - Figure #14