background image

When feeding water to the CaviBlaster

® 

power unit with the feed pump, connect 

the 1″ diameter

  clear  PVC  feed  hose  to  the  cam-lock  plug  on  the  inline  strainer 

inlet.

 

 

The feed hose has the feed pump on one end and a cam-lock socket on the other end. Insert the 
electrical plug powering the feed pump into the waterproof electrical outlet on the end of the 
power unit cart under the handle. Ensure that the knob on the plug is facing up and mates with 
the notch in the outlet cover. 

If the plug is engaged upside down, the pump will turn in reverse. 

Ensure that the feed hose is connected to the pressure pump, the feed pump is  submerged in 
water,  and  the  wiring  splice  is  kept  dry  prior  to  starting  the  feed  pump. 

Either  fresh  water  or 

seawater can be used with this system. 

Note: The feed pump has had a neoprene check valve installed in the discharge. This valve will prevent water from 
draining out of the feed hose through the feed pump when the pump is turned off. However, this check valve 
somewhat restricts the flow of water from the pump. If maximum water flow is required from the feed pump, the 
check valve and stainless retaining washer can be removed from the pump discharge by removing the black hose 

barb fitting. 

NEVER TURN OFF FEED PUMP WHILE WORKING. 

 

 

 

 

 

 

 

 

 

When feeding the CaviBlaster

® 

with an alternate water source, 

the source must supply water at a 

volume of greater than 6 gallons per minute at a maximum pressure of 70-psi

. Connect the water 

source to the inlet of the pressure pump (Figure 10). 

Ensure that the feed hose is connected to the 

pressure pump and the water is on prior to starting the pressure pump.

 

 
 
 

 
 
 
 

Summary of Contents for 0625-G

Page 1: ...Operation Maintenance Manual Model 0625 G ...

Page 2: ... of the CaviBlaster it is essential to follow these instructions Preparing the CaviBlaster system for operation 1 Inspect the CaviBlaster power unit hose and gun for any signs of damage 2 Inspect Inlet Strainer Figure 1 to ensure that it is not dirty or clogged Clean as necessary Water Inlet Figure 1 ...

Page 3: ...igure 3 Fuel Level Figure 4 4 Fill lubricating oil s to proper level s in the pressure pump Yellow cap on pump Figure 5 and engine Yellow cap on head cover Figure 6 per manufacturers operating manuals Pump Oil Yellow Cap Figure 5 Yellow Cap on head cover Figure 6 NOTE Pressure Pump Oil SAE 30W Non Detergent Figure 7 Engine Oil SAE 10W 30 Figure 8 Pressure Pump Oil Figure 7 Engine Oil Figure 8 ...

Page 4: ...wer unit connect feed pump to the water inlet connection on the power unit Figure 9 Connect Feed Pump to Water Inlet Figure 9 Inspect inlet connection Figure 10 to ensure that it is not clogged Clean if necessary Connect Feed Pump to Water Inlet Figure 10 ...

Page 5: ... Either fresh water or seawater can be used with this system Note The feed pump has had a neoprene check valve installed in the discharge This valve will prevent water from draining out of the feed hose through the feed pump when the pump is turned off However this check valve somewhat restricts the flow of water from the pump If maximum water flow is required from the feed pump the check valve an...

Page 6: ...nect the 3 8 high pressure hose to the quick connect plug under the pressure regulating unloader Figure 11 The high pressure hose has a brass quick connect socket on the end The CaviBlaster Model 0625 G can deliver the required pressure utilizing up to 300 feet of 3 8 diameter rubber hose Connect HP Hose to the quick connect under pressure regulator Figure 11 4 Move throttle to the On position fig...

Page 7: ...s and nearby personnel must use appropriate hearing protection prior to starting the engine 8 Be sure the engine run switch is on figure 12 Set the choke knob to close the choke if the engine is cold or has not been running figure 13 If the engine has been running and is warm leave the choke open Adjust the throttle lever Figure 12 one third of the way from MIN toward MAX for correct engine start ...

Page 8: ...9 Once the unit is running and warm move the throttle to Max figure 16 The system is now ready to operate figure 17 Throttle to Max position Figure 16 Overall system set up Figure 17 ...

Page 9: ...erator and other people working in the vicinity of the power unit wear appropriate hearing protection when the engine is running Gun efficient operating technique Figure 18 1 The most efficient operating technique is to hold the nozzle 2 5 inches 5 12 cm away from the surface to be cleaned and at a 25 to 45 angle to the surface being cleaned The diver needs to observe the shape of the cavitating j...

Page 10: ...e throttle lever in to the idle position and release the water pressure remaining in the hose s by moving the gun trigger to the open or ON position while under water Revert to step 1 of the operating instructions when the diver or replacement is ready to continue cleaning WARNING Although the CaviBlaster system is safe to use when submerged in water the system generates a high pressure up to 2 50...

Page 11: ...the surface being cleaned Placing the gun closer than 2 3 inches from the surface being cleaned will not allow for efficient cavitation performance and will degrade the cleaning capability of the system Figure 18 5 Wear neoprene or rubber gloves to protect the hands and follow all safety regulations that may be applicable to the work being performed 6 If the diver operating the unit must be replac...

Page 12: ...t increases or decreases the flow of water through the bypass hose when the CaviBlaster gun trigger is in the open or on position The flow of water through the bypass hose in turn determines the flow of water through the pressure hose and the gun Less flow through the bypass hose means more flow through the gun which translates to higher velocity and pressure There should always be a trickle of wa...

Page 13: ...e system and rinse the power unit with fresh water after each days use for at least 5 minutes to make sure all inside residuals are removed 3 Change the engine oil after the first month or 20 hours and every six months or 100 hours thereafter Replace the oil filter every 200 hours Use SAE 10W 30 oil for general all temperature use 4 Clean the air cleaner cover filter elements and base every three ...

Page 14: ... very safe operators should exercise care when using this equipment With the diver lance underwater the cavitation flame can be safely passed over the operators skin at normal operating distances of 2 3 from the tip of the nozzle However at very close distances typically less than 1 both nozzles can cause harm to the operator particularly in the initial instant that the system is activated For tha...

Page 15: ...ctions to ensure that they are compatible with the pressures being used and of the correct thread type and pressure rating for the intended service Refer to these Operating Instructions and to the engine and pressure pump manufacturers operation manuals for instructions or call CaviDyne LLC at 352 275 5319 with any questions CAUTION DO NOT USE IT TO CLEAN SENSITIVE SURFACES as LED Lights Underwate...