Starting the CaviBlaster® power unit:
1. Connect the garden hose to the water inlet, open the valve to supply water to the system. (Figure-4).
2. Ensure that the system is primed with water and that there are no leaks in the system. The pressure
pump is a positive displacement pump and water must be supplied under pressure. Failure to pump
feed water to the pressure pump will result in damage to the pump.
3. Connect the 3/8″ high-pressure hose to the quick-connect plug under the pressure-regulating
unloader (Figure-6). The high-pressure hose has a brass quick-connect socket on the end. The
CaviBlaster® Model 0520-E can deliver the required pressure utilizing up to 300 feet of 3/8″ diameter
rubber hose.
Figure #6 - Connect HP Hose to the quick connect under pressure regulator
4. Connect the gun to the high-pressure hose (Figure-7) and submerge the gun in water.
Figure #7 - Connecting the gun to the High Pressure Hose
Page 5
CaviBlaster 0520-E manual for more assistance please visit www.cavidyne.com